TrueEase Wiring Instructions

INSTALLATION ADDENDUM
69-2576-05
Wiring Configuration
ADVANCED MODELS (HE150/HE250/HE300)
Fig. 1. Wiring HumidiPRO (H6062) to humidify only with a call for Heat or Fan.
Fig. 2. Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent
control to program humidity calls with heat, cool, or on demand.
HumidiPRO
M35152
POWER IN
G OR W
C
OR
AIR PROVING
DEVICE
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.
USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION
TO HUMIDIFY ANY TIME THE FAN IS OPERATING.
1
1
2
3
3
2
LEFT
LEFT
OUTDOOR
SENSOR
C
R
U
U
S
S
M35153
FROM
HUMIDITY
CONTROL
POWER IN
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
1
1
RIGHT
LEFT