Datasheet

HOA1882 HOA088X HOA1870
Sensor aperture 1,52 mm [0.06 in] dia
1,52 mm x 0,25 mm
[0.06 in x 0.01 in]
1,02 mm x 0,15 mm
[0.04 in x 0.006 in]
Slot width 5,08 mm [0.20 in] 3,18 mm [1.25 in] 0,78 mm [0.07 in]
Rise/fall time (typ.) 15 ms 15 ns 15 ns
Coupled current (Ic) min. 1.8 mA 0.5 mA 0.3 mA
Collector-emitter
breakdown voltage (min.)
30 V 30 V 30 V
Mounting configuration pcb mount N, L, T, P mounting options mounting tab
Termination style 0.020 in sq leads 26 AWG UL 1429 wire leads 22 AWG UL 1007 wire leads
4 www.honeywell.com/sensing
Infrared Sensors Line Guide
Transmissive
Sensors
SD5600 SD5610 SD5620 SD5630 SDP8600 SDP8610
Package style TO-46 dome lensed TO-46 dome lensed TO-46 dome lensed TO-46 dome lensed Side-detecting Side-detecting
Package components metal metal metal metal plastic plastic
Angular response 12° 12° 12° 12° 50° 50°
Turn-on threshold
irradiance
2.5 mW/cm
2
max. 2.5 mW/cm
2
max. 0.25 mW/cm
2
0.25 mW/cm
2
2.5 mW/cm
2
max. 2.5 mW/cm
2
max.
Output logic buffer inverter buffer inverter buffer inverter
Supply voltage (range) 4.5 Vdc to 16 Vdc 4.5 Vdc to 16 Vdc 4.5 Vdc to 16 Vdc 4.5 Vdc to 16 Vdc 4.5 Vdc to 12 Vdc 4.5 Vdc to 12 Vdc
Mounting configuration through-hole through-hole through-hole through-hole through-hole through-hole
Termination style
0.018 in round
leads
0.018 in round
leads
0.018 in round
leads
0.018 in round
leads
0.020 in sq leads 0.020 in sq leads
Optoschmitt
Detectors