C. Location
CAUTION
1. This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating
water temperature should be within 45°F to 90°F (7°C to 32°C). Operation
of the icemaker, for extended periods, outside of these normal temperature
ranges may affect icemaker performance.
2. This icemaker will not work at sub-freezing temperatures. To prevent damage
to the water supply line, drain the icemaker if the air temperature is going to
gobelow32°F(0°C).See"III.C.PreparingtheIcemakerforLongStorage."
For best operating results:
•Theicemakershouldnotbelocatednexttoovens,grills,orotherhighheatproducing
equipment.
•Thelocationshouldprovidearmandlevelfoundationfortheequipment.
•Allow6"(15cm)clearanceatrear,sides,andtopforproperaircirculationandeaseof
maintenance and/or service should they be required.
D. Setup
CAUTION
Before operating the icemaker, the bin control thermostat assembly must be
installed correctly. Failure to properly install the assembly could result in ice
backup and unit damage.
1) Unpack the storage bin, and attach the 4 adjustable legs provided (bin accessory) to
the bottom of the storage bin.
2) Position the storage bin in the selected permanent location.
3) Place the icemaker on top of the storage bin.
4) Secure the icemaker to the storage bin using the 2 mounting brackets and the bolts
provided. See Fig. 2.
Fig. 2
Icemaker
Mounting Brackets
Bolts
Bin