c. Make sure the male tting and female coupling are properly aligned, then start the
connection by hand to ensure that it is not cross threaded.
d. Tighten the connection with a wrench until it is tight. At this point, the nut has
covered most of the threads on the male tting.
e. Mark a reference line on the female coupling and the remote condenser unit or
icemaker panel. Using a backup wrench on the back of the female coupling, tighten
the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 13.
Fig. 11
THREAD
SEALANT
Threads
Diaphragm
O-Ring
Fig. 12
Fig. 13
POLYOL
ESTER
(POE) OIL
PARKER
SUPER
O LUBE
Brush
Male Fitting
Apply POE Oil to
Entire Male Fitting
DO NOT USE
THREAD SEALANT
Backup
Wrench
Reference Line
1/6 Turn
Wrench
Wrench
Backup
Wrench
After Tight, Tighten an
Additional 1/6 Turn
Female Coupling
5/8"ODDischargeLine
(Insulated)
Remote Condenser Unit
3/8"ODLiquidLine
(Insulated)
Icemaker
Male Fitting
Service Loop