User guide

22
1. Icemaker
•Icemakerwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof1/2"OD
copper tubing is recommended for the icemaker water supply line.
•Anicemakerwatersupplylineshut-offvalveanddrainvalveshouldbeinstalled.
•Icemakerdrainoutletis3/4"FPT.Aminimumof3/4"ODhardpipeisrecommended
fortheicemakerdrainline.Condensationdrainoutletis3/8"ODstainlesstube.The
condensation drain line can be connected to the icemaker drain line or can be run
separately.
BinDrainOutlet3/4"FPT
IcemakerWaterSupplyLineShut-OffValve
IcemakerWaterSupplyLineDrainValve
IcemakerWaterSupplyInlet1/2"FPT
Icemaker
Drain Outlet
3/4"FPT
Condensation
Drain Outlet
3/8"OD
Stainless Tube
Bin
Icemaker
Remote Condenser Line Set Connections
Separate piping to approved drain.
Leave a 2 inch (5 cm) vertical air gap
between the end of each pipe and
the drain.
2 inch (5 cm)
air gap
Floor
Drain
Fig. 16
KM-2100SRH3
Icemaker Connection