User guide

23
2. Water-Cooled Condenser
a) Connection to an Open Drain System
•Condenserwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof3/8"OD
copper tubing is recommended for the condenser water supply line.
•Acondenserwatersupplylineshut-offvalveanddrainvalveshouldbeinstalled.
•Condenserdrainoutletis3/8"FPT.Aminimumof3/8"ODhardpipeisrecommendedfor
the condenser drain line. Drain line must be run separately.
•Insomeareas,abackowpreventermayberequiredinthecoolingwatercircuit.
KM-2100SWH3
Connection to an Open Drain System
CondenserWaterSupplyInlet1/2"FPT
IcemakerWaterSupplyInlet1/2"FPT
Icemaker
Drain Outlet
3/4"FPT
Condensation
Drain Outlet
3/8"OD
Stainless
Tube
CondenserDrainOutlet3/8"FPT
BinDrainOutlet3/4"FPT
Bin
Icemaker
Separate piping
to approved drain.
Leave a 2 inch
(5 cm) vertical air
gap between the
end of each pipe
and the drain.
IcemakerWaterSupplyLineShut-OffValve
IcemakerWaterSupplyLineDrainValve
CondenserWaterSupplyLineShut-OffValve
CondenserWaterSupplyLineDrainValve
Fig. 17
2 inch (5 cm)
air gap
Floor
Drain