Fig. 18
KM-2100SWH3
Connection to a Closed Loop System
BinDrainOutlet3/4"FPT
CondenserWaterSupplyLineShut-OffValve
CondenserWaterSupplyLineDrainValve
IcemakerWaterSupplyLineShut-OffValve
IcemakerWaterSupplyLineDrainValve
CondenserReturnOutlet3/8"FPT
IcemakerWaterSupplyInlet1/2"FPT
CondenserReturnLineShut-OffValve
CondenserReturnLineDrainValve
Icemaker
Drain Outlet
3/4"FPT
Condensation
Drain Outlet
3/8"OD
Stainless Tube
Bin
Icemaker
Separate piping to
approved drain. Leave a
2 inch (5 cm) vertical air
gap between the end of
each pipe and the drain.
2 inch (5 cm)
air gap
Floor
Drain
CondenserWaterSupplyInlet1/2"FPT
b) Connection to a Closed Loop System
•Condenserwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof3/8"OD
copper tubing is recommended for the condenser water supply line.
•Condenserreturnoutletis3/8"FPT.Aminimumof3/8"ODhardpipeisrecommendedfor
the condenser return line.
•Shut-offvalvesanddrainvalvesshouldbeinstalledatboththecondenserwatersupply
inlet and condenser return outlet.
•Thewatersupplytothecondensershouldnotdropbelow4GPM.
•Thepressuredifferentialbetweenthecondenserwatersupplyinletandcondenserreturn
outlet must be no less than 10 PSIG.
•Whenusingaglycolblend,thesolutionmixtureshouldbelessthan30%glycol.
•Inordertomaintaintheproperhighsidepressure,thecondenserwatersupplyinlet
temperature should not drop below 45°F (7°C) and the condenser return outlet
temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker
installation is complete, conrm the condenser return outlet temperature 5 minutes
after a freeze cycle starts. If the outlet temperature is not in the proper range, adjust the
water-regulating valve to bring it into range.