J. Startup
WARNING
1. All parts are factory-adjusted. Improper adjustments may adversely affect
safety, performance, component life, and warranty coverage.
2. If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
3. To prevent damage to the water pump seal, do not operate the icemaker with
thecontrolswitchinthe"WASH"positionwhenthewatertankisempty.
4. At startup, conrm that all internal and external connections are free of leaks.
5. On remote air-cooled model, the icemaker should have power for a minimum
of 4 hours prior to startup to prevent compressor damage.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3)Movethecontrolswitchonthecontrolboxtothe"ICE"position.
4) Replace the front panel in its correct position.
5) Turn on the power supply, and allow the icemaker to operate for a total of 10 minutes.
6) Turn off the power supply, then remove the front panel.
7) Remove the insulation panel. Remove the drain plug located on the lower front part of
the ice chute. See Fig. 19. Allow the water tank to drain.
8) Replace the drain plug, insulation panel, and front panel in their correct positions. Be
careful not to cross thread the drain plug.
9) Clean the storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
10) Turn on the power supply to start the automatic icemaking process.
11) When the icemaker is running, hold an ice cube in contact with the bin control
thermostat bulb. The icemaker should stop within 3 to 10 seconds. Adjustment may be
needed, particularly at higher altitude locations.
Fig. 19
Ice Chute
Cube Guides
Separators
Float Switch
Assembly
Drain Plug
Cleaning
Valve