Installation Guide

DIMENSIONS AND CLEARANCES
Provide adequate clearances between the
range and adjacent combustible surfaces. These
dimensions must be met for safe use of your
range.
Allow 30” (76.2 cm) minimum clearance between
burners and bottom of unprotected wood or
metal cabinet, or allow a 24” (61 cm) minimum
when bottom of wood or metal cabinet is
protected by no less than 1/4” (6.4 mm) thick
flame-retardant millboard covered with no less
than No. 28 MSG sheet metal (.015” [.38 mm]
thick), .015” (.38 mm) thick stainless steel, .025”
(0.64 mm) aluminum or .020” (0.5 mm) copper.
Installation of a listed microwave oven or
cooking appliance over the cooktop shall
conform to the installation instructions packed
with that appliance.
For island installation, maintain 2-1/2” minimum
from cutout to back edge of countertop and
3” minimum from cutout to side edges of
countertop.
To cabinets
below cooktop
and at the
range back
Minimum to
cabinets on
either side
of the range
30”
30”
Minimum
13”
1”
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
Front edge
of the range
side panel
forward from
cabinet
0”
To cabinets
below cooktop
and at the
range back
1/4”
1”
Minimum
clearance
to left wall
0”
18”
30"
46 3/8"
28 3/4"
w/ handle
26 1/4"
w/o handle
10 7/8"
36 1/4 " ± 1/4
CONVERTING TO LP GAS
(OR CONVERTING BACK TO
NATURAL GAS FROM LP)
This range leaves the factory set for use with
natural gas. If you want to convert to LP
gas, the conversion must be performed by a
qualified LP gas installer.
The conversion orifices and instructions can be
found on back of the range.
Keep these instructions and all orifices in case
you want to convert back to natural gas.
DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
Rear of Range
Orifice Strip
(location
may vary)
Recommended area for
120V outlet on rear wall and
area for through-the-wall
connection of pipe stub and
shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
CAUTION To prevent drafts
from affecting burner operation, seal
all openings in floor under appliance
and behind appliance wall.