0.7.01.19 UNRECOVERABLE condition—EMU ESI driver failure
The EMU has detec
ted an internal hardware problem. This condition report remains active until the
problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the c ondition report.
2. Reset the EMU.
3. Observe the EMU to ensure the error does not recur within the rst minute.
4. If the error do es recur, contact your HP authorized service representative. The EMU is inoperative
andmustberep
lacedassoonaspossible.
Transceiver conditions
The format of a transceiver condition report is 0.F.en.ec,where:
0.F. is the transceiver element type number
en. is the t wo-character transceiver element number (see Figure 44)
ec is the error code
CXO7954
A
3 1
4 2
Figure 44 Transceiver elem ent numbering
1. Transceiver 01 2. Transceiver 02
3. Transceiver 03
4. Transceiver 04
0.F.en.01 CRITICAL condition—Transceiver incompatibility
The transceivers on this link are not the same type or they are incompatible with the I/O module. This
error prevents the controller from establishing a link with the enclosure disk drives and eliminates the
enclosuredual-loopcapability.Thiserrorremainsactiveuntiltheproblemiscorrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
0.F.en.02 CRITICAL condition—Transceiver data signal lost
This symptom can occur when a controller has been powered off or a cable has been removed from
the tran
sceiver. The transceiver can no longer detect a data signal. This error prevents the controller
from tr
ansferring data on a loop and eliminates the enclosure dual-loop capability. This error remains
active
until the problem is xed.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
0.F.en.03CRITICALconditionTransceiverbre channel drive enclosure bus fault
The system has detected a Fibre Channel drive enclosure bus fault involving a transceiver. This error
prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capabilit y.
128
EMU-generated condition reports