- Hewlett-Packard Printer Owner's Manual

60
 !!

All configuration changes must be made through the master
configuration port. This master configuration port has access to all
options of configuration mode. Please use the following procedure to
configure your Print Master 700D, 700E, or 700F model:
1. Connect a dumb terminal (or a PC running a terminal emulation
program) to the master configuration port which is Port 6 on the
706D and 706E; Port 8 on the 708D, 708E and 708F; Port 10
on the 710E and 710F. From the factory, all serial ports are
preset at 9600 baud rate, 8 word size, 1 stop bit, no parity and
XON/XOFF disabled.
NOTE:
If you wish to use the BayTech TERM.EXE program to
configure your unit, refer to the instructions on the following
page.
2. Make sure the keyboard of your computer is in the CAPS
LOCK position.
All ports on Print Master must be off-line (i.e., all LEDs must be
off except the green power LED).
Send from the keyboard of the terminal or the PC
Control-T
followed by capital
C
. These characters will not appear at on
the CRT screen, but Print Master will respond with the main
configuration menu.
If any red LEDs on Print Master illuminate when
Control-T
and
C are sent or if Print Master gives no response (no menus
appear), this indicates that an incorrect character sequence
has been received. If this occurs, wait for Print Master to
timeout (LEDs will go out) and resend
Control-T
and capital C.