Turbo16/4 Token Ring Network ISA Adapter 72H3482 Installation Guide
Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
1 Connecting to a Netware 3.12 Server Windows for Workgroups 1 Connecting to a Netware 3.12 Server Windows for Workgroups Requirements • HP Vectra VL8 with Windows for Workgroups 3.11 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.20 Driver Name: IBMTOK.DOS Size: 18KB Date: 6/13/96] • Microsoft Windows for Workgroups 3.11 media. • Novell Netware 3.12 server that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols.
1 Connecting to a Netware 3.12 Server Windows for Workgroups ❒ NetWare Client-32 ❒ NetBIOS ❒ IEEE 802.2 8 Select the Continue button. 9 At the “IBM LAN Client Configuration” screen, use the defaults and select the Install button. 10 Insert disks 2 – 4 when prompted. 11 When you have received notification that the installation has completed, select “OK”. 12 At the “Installation Log” screen, select “Close”. 13 When the LANAID v2.20 for Turbo 16/4 Token-Ring ISA screen comes up, chose “Adapter Configuration”.
1 Connecting to a Netware 3.12 Server Windows 95 SR2 Windows 95 SR2 Requirements • HP Vectra with Windows 95 SR2 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: NETIBM4.INF Size: 30KB Date: 1/30/98 • Microsoft Windows 95 SR2 media. • Novell Netware 3.12 server that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols.
1 Connecting to a Netware 3.12 Server Windows 95 SR2 7 Reboot the machine and allow it to boot to Windows 95. 8 Windows 95 SR2 should automatically recognize the IBM Auto 16/4 TR adapter card. If you are using a Vectra VL8, go directly to step 9. If you are using a Vectra VE7/VE8, follow the instructions below to complete the installation. a Click on "Next" to provide the driver, then click on "Other Locations.
1 Connecting to a Netware 3.12 Server Windows 95 SR2 “Workgroup”, and “Computer Description” and click on “OK.” (If you do not have a Computer name, Workgroup name and Computer description, contact your network administrator) 16 When prompted for your Windows 95 CD-ROM, click on “OK.” 17 Set the path to your Windows 95 files and click on “OK.” (If you have an HP pre-loaded HDD, set the path statement C:\MASTERS\WIN95\SYSTEM\CABS\”). 18 Click on “YES” to complete installation and restart the machine.
1 Connecting to a Netware 3.
2 Connecting to a Netware 4.11 Server Windows for Workgroups 2 Connecting to a Netware 4.11 Server Windows for Workgroups Requirements • HP Vectra VL8 with Windows for Workgroups 3.11 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.20 Driver Name: IBMTOK.DOS Size: 18KB Date: 6/13/96 • Microsoft Windows for Workgroups 3.11 media. • Novell Netware 4.1 server that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols.
2 Connecting to a Netware 4.11 Server Windows for Workgroups ❒ NetWare Client-32 ❒ NetBIOS ❒ IEEE 802.2 8 Select the Continue button. 9 At the “IBM LAN Client Configuration” screen, use the defaults and select the Install button. 10 Insert disks 2 – 4 when prompted. 11 When you have received notification that the installation has completed, select “OK”. 12 At the “Installation Log” screen, select “Close”. 13 When the LANAID v2.20 for Turbo 16/4 Token-Ring ISA screen comes up, chose “Adapter Configuration”.
2 Connecting to a Netware 4.11 Server Windows 95 SR2 Windows 95 SR2 Requirements • HP Vectra with Windows 95 SR2 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: NETIBM4.INF Size: 30KB Date: 1/30/98 • Microsoft Windows 95 SR2 media. • Novell Netware 4.1 server that supports Net BEUI, NWLink IPX/SPX, and NWLink NetBIOS transfer protocols.
2 Connecting to a Netware 4.11 Server Windows 95 SR2 7 Reboot the machine and allow it to boot to Windows 95. 8 Windows 95 SR2 should automatically recognize the IBM Auto 16/4 TR adapter card. If you are using a Vectra VE7/VE8, follow the instructions below to complete the procedure. If you are using a Vectra VL8, go directly to step 9. a Click on "Next" to provide the driver, then click on "Other Locations.
2 Connecting to a Netware 4.11 Server Windows 95 SR2 “Workgroup”, and “Computer Description” and click on “OK.” (If you do not have a Computer name, Workgroup name and Computer description, contact your network administrator) 16 When prompted for your Windows 95 CD-ROM, click on “OK.” 17 Set the path to your Windows 95 files and click on “OK.” (If you have an HP pre-loaded HDD, set the path statement C:\MASTERS\WIN95\SYSTEM\CABS\”). 18 Click on “YES” to complete installation and restart the machine.
2 Connecting to a Netware 4.
3 Connecting to a Windows NT 3.51 Server Windows for Workgroups 3 Connecting to a Windows NT 3.51 Server Windows for Workgroups Requirements • HP Vectra with Windows for Workgroups 3.11 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.20 Driver Name: IBMTOK5.386 Size: 46K Date: 9/28/96 • Microsoft Windows for Workgroups 3.11 media. • Microsoft Windows NT 3.51 server that supports Net BEUI, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
3 Connecting to a Windows NT 3.51 Server Windows for Workgroups 5 Type “/VIEW” and verify the settings as listed above under the heading “Device Configuration.” 6 Make any changes, exit LANAID, and remove the drivers diskette. 7 Reboot the machine to Windows, open the “NETWORK” folder, and double-click the “NETWORK SETUP” icon. 8 Select “Networks” and choose “Install Microsoft Windows Network:” and click on “OK.” 9 Click on “Drivers” and then on “Add Adapter.
3 Connecting to a Windows NT 3.51 Server Windows for Workgroups 12 Select “IBM Turbo 16/4 Token-Ring ISA Adapter, NDIS2 only” and click on “OK.” 13 Accept the default “Network Drivers” and click on “Close.” ❒ IBM Token-Ring ISA Adapter, NDIS2 only [NDIS2] ❒ Microsoft NetBEUI ❒ IPX/SPX Compatible Transport with NetBIOS 14 At the “Network Setup” dialog box, click “OK.” 15 Set your User Name, Workgroup, and Computer Name and click “OK.
3 Connecting to a Windows NT Server 3.51 Windows 95 SR2 Windows 95 SR2 Requirements • HP Vectra with Windows 95 SR2 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: NETIBM4.INF Size: 30KB Date: 1/30/98 • Microsoft Windows 95 SR2 media. • Microsoft Windows NT 3.51 server that supports Net BEUI, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
3 Connecting to a Windows NT Server 3.51 Windows 95 SR2 10 When Windows 95 has loaded, click on “Start” then “Settings” and open the “Control Panel.” 11 Double-Click the “Network” icon and click on “Add.” 12 Select to add an “Adapter”, click on “Add” and then click on “Have Disk.” 13 In the “Install From Disk” window, insert the IBM TR drivers disk 2 of 4, set the path to “A:\” and click on “OK.
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version3.51 Windows NT Workstation Version3.51 Requirements • HP Vectra with Windows NT Workstation 3.51 installed. • IBM Turbo 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: IBMTOK5.SYS Size: 51KB Date: 9/28/96 • DOS and MS-Windows NT workstation 3.51 media. • Microsoft NT 3.51 server that supports Net BEUI, TCP/IP, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version3.51 10 Click on “YES” in the “Network Settings” dialog box, and NT Networking will be installed on your computer. 11 Insert the Windows NT Workstation CD. 12 In “Windows NT Setup”, set the path to your NT files and click on the “Continue” button.
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version3.51 25 At the “Domain/Workgroup Settings” dialog box, click on “OK” to accept the default “Workgroup” as your workgroup name. (If you do not have the required information, contact your network administrator.) 26 To complete the installation, remove the floppy disk , and click on “Restart Computer” button in the “Windows NT Workstation Networking Setup” dialog box.
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version3.
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version 4.0 Windows NT Workstation Version 4.0 Requirements • HP Vectra VL8 with Windows NT Workstation 4.0 installed. • IBM Turbo 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: IBMTOK5.SYS Size: 51KB Date: 9/28/96 • DOS and MS-Windows NT workstation 3.51/4.0 media. • Microsoft NT 3.51 server that supports Net BEUI, TCP/IP, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
3 Connecting to a Windows NT Server 3.51 Windows NT Workstation Version 4.0 10 In the Network Setup Wizard dialog box, make sure that “Wired to the Network” is checked and click on “Next”. 11 Click on “Select from list” and click on “Have Disk” and set path to “A:\NT” (If you have a preloaded HDD, set path to “C:\Masters\LanDrv\Turbo164\DISK2\NT”) 12 In the “Select OEM Option” dialog box, make sure that “IBM Shared RAM Token Ring Adapter” is highlighted and click on “OK” and then click on “Next”.
4 Connecting to a Windows NT 4.0 Server Windows for Workgroups 4 Connecting to a Windows NT 4.0 Server Windows for Workgroups Requirements • HP Vectra with Windows for Workgroups 3.11 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: IBMTOK5.386 Size: 46K Date: 9/28/96 • Microsoft Windows for Workgroups 3.11 media. • Microsoft Windows NT 4.0 server that supports Net BEUI, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
4 Connecting to a Windows NT 4.0 Server Windows for Workgroups 5 Type “/VIEW” and verify the settings as listed above under the heading “Device Configuration.” 6 Make any changes, exit LANAID, and remove the drivers diskette. 7 Reboot the machine to Windows, open the “NETWORK” folder, and double-click the “NETWORK SETUP” icon. 8 Select “Networks” and choose “Install Microsoft Windows Network:” and click on “OK.” 9 Click on “Drivers” and then on “Add Adapter.
4 Connecting to a Windows NT 4.0 Server Windows for Workgroups on “OK.” 13 Accept the default “Network Drivers” and click on “Close.” • IBM Token-Ring ISA Adapter, NDIS2 only [NDIS2] • Microsoft NetBEUI • IPX/SPX Compatible Transport with NetBIOS 14 At the “Network Setup” dialog box, click “OK.” 15 Set your User Name, Workgroup, and Computer Name and click “OK.” (If you do not have the required information, contact your network administrator) 16 When prompted for the file “LT2.
4 Connecting to a Windows NT 4.
4 Connecting to a Windows NT Server 4.0 Windows 95 SR2 Windows 95 SR2 Requirements • HP Vectra with Windows 95 SR2 installed. • IBM Auto 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: NETIBM4.INF Size: 30KB Date: 1/30/98 • Microsoft Windows 95 SR2 media. • Microsoft Windows NT 4.0 server that supports Net BEUI, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
4 Connecting to a Windows NT Server 4.0 Windows 95 SR2 7 Reboot the machine and allow it to boot to Windows 95. 8 Windows 95 SR2 should automatically recognize the IBM Auto 16/4 TR adapter card. If you are using a Vectra VL8, go directly to step 9. If you are using a Vectra VE7/VE8, follow the instructions below to complete the installation. a Click on "Next", on "Other Locations", and insert the IBM TR drivers disk 2 of 4. b Set the path to "A:\WIN95\" and hit enter.
4 Connecting to a Windows NT Server 4.0 Windows 95 SR2 “Workgroup”, and “Computer Description” and click on “OK.” (If you do not have a Computer name, Workgroup name and Computer description, contact your network administrator) 16 When prompted for your Windows 95 CD-ROM, click on “OK.” 17 Set the path to your Windows 95 files and click on “OK.” (If you have an HP pre-loaded HDD, set the path statement C:\MASTERS\WIN95\SYSTEM\CABS\”). 18 Click on “YES” to complete installation and restart the machine.
4 Connecting to a Windows NT Server 4.0 Windows NT Workstation Version3.51 Windows NT Workstation Version3.51 Requirements • HP Vectra VL8 with Windows NT Workstation 3.51 installed. • IBM Turbo 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: IBMTOK5.SYS Size: 51KB Date: 9/28/96 • DOS and MS-Windows NT workstation 3.51 media. • Microsoft NT 4.0 server that supports Net BEUI, TCP/IP, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
4 Connecting to a Windows NT Server 4.0 Windows NT Workstation Version3.51 10 Click on “YES” in the “Network Settings” dialog box, and NT Networking will be installed on your computer. 11 Insert the Windows NT Workstation CD. 12 In “Windows NT Setup”, set the path to your NT files and click on the “Continue” button.
4 Connecting to a Windows NT Server 4.0 Windows NT Workstation Version3.51 25 At the “Domain/Workgroup Settings” dialog box, click on “OK” to accept the default “Workgroup” as your workgroup name. (If you do not have the required information, contact your network administrator.) 26 To complete the installation, remove the floppy disk , and click on “Restart Computer” button in the “Windows NT Workstation Networking Setup” dialog box.
4 Connecting to a Windows NT Server 4.0 Windows NT Workstation Version 4.0 Windows NT Workstation Version 4.0 Requirements • HP Vectra VL8 with Windows NT Workstation 4.0 installed. • IBM Turbo 16/4 TR adapter and drivers diskettes ver 2.1 Driver Name: IBMTOK5.SYS Size: 51KB Date: 9/28/96 • DOS and MS-Windows NT workstation 4.0 media. • Microsoft NT 4.0 server that supports Net BEUI, TCP/IP, NWLink IPX/ SPX, and NWLink NetBIOS transfer protocols.
4 Connecting to a Windows NT Server 4.0 Windows NT Workstation Version 4.0 10 In the Network Setup Wizard dialog box, make sure that “Wired to the Network” is checked and click on “Next”. 11 Click on “Select from list” and click on “Have Disk” and set path to “A:\NT” (If you have a preloaded HDD, set path to “C:\Masters\LanDrv\Turbo164\DISK2\NT”) 12 In the “Select OEM Option” dialog box, make sure that “IBM Shared RAM Token Ring Adapter” is highlighted and click on “OK” and then click on “Next”.
4 Connecting to a Windows NT Server 4.0 Windows NT Workstation Version 4.0 26 At the “Domain/Workgroup Settings” dialog box, click on “OK” to accept the default “Workgroup” as your workgroup name. (If you do not have the required information, contact your network administrator.) 27 To complete the installation, remove the floppy disk, and click on “Finish” button in the “Network Setup Wizard” dialog box.
4 Connecting to a Windows NT Server 4.0 Windows NT Workstation Version 4.
Version Number IBM Turbo 16/4 Rev.