- Hewlett-Packard Monitor User's Guide

Chapter 5
Hardware Monitor Configuration Files
Monitor-Specific and Global Configuration Files
116
SEVERITY_ACTION INFORMATION NOTIFY
SEVERITY_ACTION MINOR_WARNING NOTIFY
SEVERITY_ACTION MAJOR_WARNING NOTIFY
SEVERITY_ACTION SERIOUS NOTIFY
SEVERITY_ACTION CRITICAL NOTIFY
#****************************************************************************#
#* *#
#* cfg-verb event# --severity--- action- ---------description------------- *#
#* *#
#****************************************************************************#
DEFINE_EVENT 3 INFORMATION DEFAULT # Target Operating conditions changed
DEFINE_EVENT 4 INFORMATION DEFAULT # Microcode has been changed
DEFINE_EVENT 6 INFORMATION DEFAULT # Inquiry data has changed
DEFINE_EVENT 7 CRITICAL DEFAULT # Failed write operation
DEFINE_EVENT 8 CRITICAL DEFAULT # Auto reallocation failed
DEFINE_EVENT 9 CRITICAL DEFAULT # Reconstruction Failed (write)
DEFINE_EVENT 10 SERIOUS DEFAULT # Reconstruction failed (read)
DEFINE_EVENT 11 CRITICAL DEFAULT # Unrecovered Read/write error
DEFINE_EVENT 12 CRITICAL DEFAULT # Deferred error caused drive warning
DEFINE_EVENT 13 CRITICAL DEFAULT # Hardware component diag failure
DEFINE_EVENT 14 CRITICAL DEFAULT # Failed testUnit ready command
DEFINE_EVENT 15 CRITICAL DEFAULT # Format unit command failed
DEFINE_EVENT 16 SERIOUS DEFAULT # Mode select command failed
DEFINE_EVENT 17 SERIOUS DEFAULT # Drive failed because deferred error
DEFINE_EVENT 18 CRITICAL DEFAULT # Drive replacement error
DEFINE_EVENT 19 MAJOR_WARNING DEFAULT # Excessive Media error rate
DEFINE_EVENT 20 MAJOR_WARNING DEFAULT # Excessive Seek Error rate
DEFINE_EVENT 21 MAJOR_WARNING DEFAULT # Excessive grown defects
DEFINE_EVENT 22 SERIOUS DEFAULT # No response from a drive
DEFINE_EVENT 23 SERIOUS DEFAULT # Communication errors
DEFINE_EVENT 24 SERIOUS DEFAULT # No drive present when it should be
DEFINE_EVENT 25 CRITICAL DEFAULT # Subsystem component failure
DEFINE_EVENT 26 MINOR_WARNING DEFAULT # AC power fail. On battery.
DEFINE_EVENT 27 CRITICAL DEFAULT # AC power fail. 2 minutes to shutdown
DEFINE_EVENT 28 CRITICAL DEFAULT # AC power fail, DC power gone.
DEFINE_EVENT 29 INFORMATION DEFAULT # AC power was lost, now back