application notes hp OpenView storage management appliance software event code definitions Product Version: 2.0 First Edition (December 2002) Part Number: AA-RTDKA-TE This document describes the event codes used in notification messages generated by the HP OpenView Storage Management Appliance software V2.0. Additional information and other HP OpenView documentation are available at: http://h18000.www1.hp.com/products/sanworks/managementappliance.
© Hewlett-Packard Company, 2002. All rights reserved. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright.
Application Notes Contents Application Notes Contents These Application Notes provide listings of the various event codes displayed by the HP OpenView Storage Management Appliance.
Introduction Introduction The Storage Management Appliance can generate notification messages to any number of users in response to events. A notification message, including the source of the event, date, time, event code, and event description, can be sent to a standard e-mail address or to an e-mail pager address. This document provides a complete list of the events logged by the Storage Management Appliance. The lists of events are presented in tables with one table for each application or vendor.
Storage Management Appliance Event Codes Storage Management Appliance Event Codes The Storage Management Appliance’s core services—discovery, event notification, and automation—generate the events listed below. The system records these events in the Storage Management Appliance Event Log. Table 2: Storage Management Appliance Event Codes Event ID Event Code Severity Description 202 880A00CA 2 Discovery %1 started. 203 880A00CB 2 Discovery %1 completed. 204 880A00CC 2 New device found: %1.
Storage Management Appliance Audit Codes Storage Management Appliance Audit Codes The Storage Management Appliance generates audits in response to most user-initiated operations. Activities such as creating or running a discovery generate audits that are recorded in the Storage Management Appliance Audit Log. Table 3: Storage Management Appliance Audit Codes Event ID 6 Event Code Severity Description 100 8C0A0064 2 Installation of %1 on appliance %2.
Storage Management Appliance Audit Codes Table 3: Storage Management Appliance Audit Codes (Continued) Event ID Event Code Severity Description 407 8C0A0197 2 Deletion of notification settings from user %1 and transferred to user %2. 500 8C0A01F4 2 Starting backup to network share %1. 501 8C0A01F5 2 Completion of backup operation that was started to network share %1. See %2 file on Management Appliance %3 for details.
Storage Management Appliance Audit Codes Table 3: Storage Management Appliance Audit Codes (Continued) 8 Event ID Event Code Severity Description 1002 8C0A03EA 2 Changing Management Appliance membership to domain %1. 1003 8C0A03EB 2 Shutdown of Management Appliance. 1004 8C0A03EC 2 Changing domain/workgroup membership. 1005 8C0A03ED 2 Restarting Management Appliance. 1006 8C0A03EE 2 Scheduling Management Appliance for %1.
NetApp Filers Event Codes NetApp Filers Event Codes The following events are generated by NetApp Filer devices and are recorded in the Storage Management Appliance Event Log. A number of these events are associated with user-defined traps and most indicate a condition that is likely to have a negative impact on operations. A small number of events mark a return to normal operation after some period of abnormal operation. The Storage Management Appliance supports the NetApp MIB version 1.2.
NetApp Filers Event Codes Table 4: NetApp Filer Event Codes (Continued) Event ID 10 Event Code Severity Description 124 880E007C 5 The NVRAM battery is fully discharged. 125 880E007D 4 The charge in the NVRAM battery is low. 126 880E007E 5 A node in a Cluster FailOver configuration failed. Its partner will assume service for the failed node. 127 880E007F 5 The partner has taken over for a failed cluster node. 128 880E0080 2 A cluster node has resumed operation.
HP StorageWorks and McData Switch Event Codes HP StorageWorks and McData Switch Event Codes The following events are generated by HP StorageWorks switches and McData switches and are recorded in the Storage Management Appliance Event Log. Many of these event types have several possible states and each state has an appropriate severity code. The Storage Management Appliance supports the following StorageWorks and McData MIB versions: ■ V1.9 for the ED-5000 series ■ V1.10 for the EF-6000 series ■ V1.
HP StorageWorks and McData Switch Event Codes Table 5: HP StorageWorks and McData Event Codes (Continued) Event ID 12 Event Code Possible States Severity Description 108 880C006C N/A 2 Device WWN: %1 currently attached to Port %2 has either successfully connected or is currently being rejected due to a Port Binding violation.%n An ef6000PortBindingViolation(3) is generated whenever the switch detects that a port binding violation occurs. 109 880C006D N/A 2 Threshold Alert.
HP StorageWorks SAN and Brocade Switch Event Codes HP StorageWorks SAN and Brocade Switch Event Codes The following events are generated by HP StorageWorks SAN switches and Brocade switches and are recorded in the Storage Management Appliance Event Log. Many of these event types have several possible states and each state has an appropriate severity code. The Storage Management Appliance supports the StorageWorks SAN and Brocade MIB version 4.0.
HP StorageWorks SAN and Brocade Switch Event Codes Table 6: StorageWorks SAN and Brocade Switch Event Codes (Continued) Event ID 14 Event Code Possible States Severity Description 109 8802006D informational normal faulty 2 2 7 Fabric Watch has generated an event.%n Threshold %3 in Class/Area %1 at index %2 has generated event %7 with %5 on %6.%n This event is %8%n SSN: %9%n GroupName: %10%n GroupType: %11%n GroupMemPosition: %12%n Trap sent by Fabric Watch to notify of an event.
HSG Element Manager Event Codes HSG Element Manager Event Codes The HSG Element Manager is an application provided with the Storage Management Appliance and used to configure and monitor HSG80/60 storage elements. The HSG Element Manager generates events that help a user understand the status of both the manager application and the storage elements. The system records these events in the Storage Management Appliance Event Log.
HSG Element Manager Event Codes Table 7: HSG Element Manager Event Codes (Continued) Event ID 16 Event Code Severity Description 6036 88011794 3 Device not found.
HSG Element Manager Event Codes Table 7: HSG Element Manager Event Codes (Continued) Event ID Event Code Severity Description 6077 880117BD 2 Power supply is now good. %1 6078 880117BE 6 Fan has gone bad. %1 6079 880117BF 2 Fan is now good. %1 6080 880117C0 6 High Temperature detected. %1 6081 880117C1 2 Temperature is within optimal range. %1 6082 880117C2 6 Airflow is bad. %1 6083 880117C3 2 Airflow is now good.
HSG Element Manager Event Codes Table 7: HSG Element Manager Event Codes (Continued) Event ID 18 Event Code Severity Description 6118 880117E6 2 Item is already used 6119 880117E7 2 Device %1 added to Spare Set 6120 880117E8 2 Device %1 removed from Spare Set 6121 880117E9 2 Device removed from Failed Set 6122 880117EA 4 Attempt to expand Virtual Disk failed.
HSG Element Manager Event Codes Table 7: HSG Element Manager Event Codes (Continued) Event ID Event Code Severity Description 6159 8801180F 2 Unit is used by another configuration 6160 88011810 2 Unit is a Snapshot source 6161 88011811 2 Subsystem firmware does not support snapshots 6162 88011812 2 Subsystem does not have peer to peer support enabled 6163 88011813 2 HSGSubsystem Miscellaneous info 6164 88011814 2 Mirror cache is not enabled 6165 88011815 2 Controller cache si
HSG Element Manager Event Codes Table 7: HSG Element Manager Event Codes (Continued) Event ID 20 Event Code Severity Description 7007 88011B5F 4 Invalid SHOW DEV FULL output 7008 88011B60 4 HSGSubsystem API has received Invalid show connection output. %1 7009 88011B61 3 HSGSubsystem API received modification request but no changes were found. %1 7010 88011B62 3 HSGSubsystem API received delete request but no changes were found.
HSV Element Manager Event Codes HSV Element Manager Event Codes The HSV Element Manager is an application provided with the Storage Management Appliance that is used to configure and monitor HSV110 Array Controllers. The HSV Element Manager generates controller events and management agent events that help users understand the status of both the manager application and the storage elements. The Storage Management Appliance supports the HSV MIB version 2.0.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 771 88030303 2 3 3 Storage Cell: %1 Event Code: %2 Description: The HSV110 controller has begun booting. 772 88030304 2 3 4 Storage Cell: %1 Event Code: %2 Description: The HSV110 controller, identified in the node_name field, has finished the process of bringing the Storage System, identified in the cell_tag fields, online.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1027 88030403 6 4 3 Storage Cell: %1 Event Code: %2 Description: An unexpected event occurred while a termination event was being processed. The value contained in the uei.type field describes the event as follows: 0 = Unrecognized Unexpected Event code. 1 = Power failure before initialization could complete.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1029 88030405 2 4 5 Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log validation failed. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi structure, and the minfo.scelmi structure show the state of the Storage System Event Log at the time of the failure.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1033 88030409 2 4 9 Storage Cell: %1 Event Code: %2 Description: The Storage System Termination Event Log validation completed successfully. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the validated state of the Storage System Termination Event Log.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1536 88030600 6 6 0 Storage Cell: %1 Event Code: %2 Description: A physical disk drive has reported that it has exceeded its failure prediction threshold. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1539 88030603 3 6 3 Storage Cell: %1 Event Code: %2 Description: A frame sent to a physical disk drive or another HSV110 controller via the mirror port or a Drive Enclosure Environmental Monitoring Unit has timed out. The identity of the intended recipient is contained in the device field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1543 88030607 3 6 7 Storage Cell: %1 Event Code: %2 Description: A Target Discovery Service Descriptor frame sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1546 8803060a 2 6 a Storage Cell: %1 Event Code: %2 Description: A physical disk drive has reported numerous check condition errors. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1550 8803060e 6 6 e Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1554 88030612 2 6 12 Storage Cell: %1 Event Code: %2 Description: The retry count for a task assigned to a Drive Enclosure Environmental Monitoring Unit has been exhausted. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1560 88030618 2 6 18 Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental Monitoring Unit has begun updating its code. Do not power down this drive enclosure until the code update has completed. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 1564 8803061c 3 6 1c Storage Cell: %1 Event Code: %2 Description: A non-data exchange frame sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2311 88030907 2 9 7 Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel port identified in the attribute.value.str field and located on the rear panel of the HSV110 controller identified in the handle field has transitioned to the NORMAL state. The attribute.type field contains the value 4. The value.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2324 88030914 6 9 14 Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The state values that may be found in the value.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2333 8803091d 6 9 1d Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery assembly ‘1’ located within the HSV110 controller identified in the handle field has transitioned from the IN USE to NOT IN USE state indicating that the battery assembly has malfunctioned.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2340 88030924 2 9 24 Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘2’ blower assembly located within the HSV110 controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower has been reinstalled.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2347 8803092b 6 9 2b Storage Cell: %1 Event Code: %2 Description: The ‘2’ blower/power supply located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the ‘2’ blower/power supply assembly internal identifier value: 2. The value.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2357 88030935 2 9 35 Storage Cell: %1 Event Code: %2 Description: The Disk Group identified in the handle field was created. 2358 88030936 2 9 36 Storage Cell: %1 Event Code: %2 Description: The Physical Disk Drive identified in the handle field was discovered.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2371 88030943 2 9 43 Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified in the handle field has joined the Storage System. If the handle field is zero, the HSV110 controller identity could not be obtained due to an unexpected state transition.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2410 8803096a 2 9 6a Storage Cell: %1 Event Code: %2 Description: The Enabled/Disabled state of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Enabled/Disabled state. The new_attr.value.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2417 88030971 2 9 71 Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified in the handle field received a request to shutdown. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2506 880309ca 6 9 ca Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 5 (FAILED). The value.ul2 field contains the old state.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 2513 880309d1 6 9 d1 Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified in the handle field needs attention.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3082 88030c0a 2 c a Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has been reset due to site failover. The following fields are not valid: status, blocks, vda. 3084 88030c0c 2 c c Storage Cell: %1 Event Code: %2 Description: The specified destination virtual disk has successfully completed a merge.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3332 88030d04 6 d 4 Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is capable of operating at the loop link rate established by the drive enclosure I/O module was found to be running at a different rate.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3399 88030d47 6 d 47 Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is not operating properly. This could affect the drive enclosure air flow and cause an over temperature condition.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3419 88030d5b 3 d 5b Storage Cell: %1 Event Code: %2 Description: A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3441 88030d71 2 d 71 Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure Environmental Monitoring Unit error has occurred. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure identified in the dencl_num field within the rack identified in the rack_num field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3459 88030d83 6 d 83 Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental Monitoring Unit has experienced a hardware failure. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure identified in the dencl_num field within the rack identified in the rack_num field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3509 88030db5 6 d b5 Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply current sensor out of range condition has been reported. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure identified in the dencl_num field within the rack identified in the rack_num field.
HSV Element Manager Event Codes Table 8: HSV Element Manager Event Codes: Controller Events (Continued) Event ID Event Code Severity SWC ID Evt. No. 3564 88030dec 3 d ec Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module invalid NVRAM read error has occurred. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure identified in the dencl_num field within the rack identified in the rack_num field.
HSV Element Manager Event Codes Management Agent Events Table 9 shows events generated by the HSV Management Agent, which are logged in the Storage Management Appliance Event Log. The Event Number (Evt. No.) codes can be used to correlate events recorded in the Management Agent Event Log of the HSV Element Manager with the events logged in the Storage Management Appliance Event Log. Table 9: HSV Element Manager Event Codes: Management Agent Events Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No. 22069 88035635 2 2069 Storage Cell: %1 Entry updated successfully in the password file Event Code: %2 Description: %3 22070 88035636 2 2070 Storage Cell: %1 Entry discarded successfully in the password file Event Code: %2 Description: %3 22071 88035637 2 2071 Storage Cell: %1 Storage system is in an unknown state.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No. 23090 88035a32 2 3090 Storage Cell: %1 The contents of this file appear to be invalid Event Code: %2 Description: %3 23091 88035a33 2 3091 Storage Cell: %1 The MIB failed to build due to a missing parse file.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No. 32003 88037d03 2 12003 Storage Cell: %1 Unable to process command at this time. Retry the command or check all connections.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No. 36040 88038cc8 2 16040 Storage Cell: %1 Ema EMU In Load State. Do Not Power Off.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No. 38075 880394bb 2 18075 Storage Cell: %1 Api Modify monitor properties successfull Event Code: %2 Description: %3 38076 880394bc 2 18076 Storage Cell: %1 Api Element name too long. Maximum is 20 characters. Event Code: %2 Description: %3 38079 880394bf 2 18079 Storage Cell: %1 Api The basic license cannot be validated.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued) Event ID Event Code Severity Evt. No.
HSV Element Manager Event Codes 80 Storage Management Appliance Software Event Code Definitions Application Notes