Hitachi Dynamic Link Manager Software Users Guide for Windows (6.6) (HIT5201-96005, April 2011)

7. Utility Reference
287
DLMgetras utility. The output-destination folders shown in Table 7-1: List of
Error Information Collected by the DLMgetras Utility for Collecting Error
Information are created in a folder of your choosing, and the information is then
stored in the output-destination folders.
-eventlogtime yyyy/mm/dd
The utility obtains logs from each application, system, and security event log. The
logs obtained are those output after 00:00 on the date yyyy
/mm/dd. Specify the
date in the yyyy
/mm/dd format.
-eventlogsize {all | maximum-file-length}
all
Logs from all applications, systems, and security event logs are obtained.
maximum-file-length
The utility obtains logs from each application, system, and security event
log. The logs are obtained, starting from the most recent log, until the log size
reaches maximum-file-length. Specify the log size in MB. The specifiable
value ranges from 1 to 4096.
-h
Displays the format of the DLMgetras utility.
Note:
You cannot specify the
-eventlogsize {all | maximum-file-length}
parameter together with the
-eventlogtime yyyy/mm/dd parameter.
If neither the
-eventlogsize {all | maximum-file-length} parameter
nor the
-eventlogtime yyyy/mm/dd parameter are specified, the utility's
default is to obtain a maximum of 8 MB of event log data.
7.2.3 List of Collected Error Information
Table 7-1: List of Error Information Collected by the DLMgetras Utility for
Collecting Error Information lists the types of error information that is collected by the
DLMgetras utility in the target error information collection folder.
Table 7-1: List of Error Information Collected by the
DLMgetras Utility for
Collecting Error Information
Folder that stores collected
files
#1
Files Explanation
Just under the folder to which
collected information is output
getrasn.log The log file generated when DLMgetras
is executed.