HiCommand Dynamic Link Manager (HDLM) for Windows Systems User's Guide (HIT5201-96001, January 2008)

HiCommand
®
Dynamic Link Manager (HDLM) for Windows
®
Systems User’s Guide 189
When using the TagmaStore USP, the display format for the following items is different from
that for other storage systems:
A channel adapter number is assigned to each channel adapter. In Figure 6.8, these
numbers are CHA-1E, CHA-1F, and so on.
The port numbers for each channel adapter can be displayed in the minimized, or
expanded modes.
When the channel adapter ports are displayed in the minimized mode, all ports
belonging to each channel adapter are displayed after being aggregated into one channel
adapter port number. In
Figure 6.8, these numbers are 1A-7D, 1E-7H, and so on.
When the channel adapter ports are displayed in the expanded mode, 16 channel
adapter port numbers for each channel adapter are displayed. In
Figure 6.8, these
numbers are 1J, 3J, and so on.
If you are using Universal Storage Platform V, the Configuration view is not displayed. In the
view frame, the KAPL02087-I message is displayed. The following buttons and check boxes
for the Configuration view are not displayed:
Online button
Offline button
Type check box
Status check box
The following describes each window component:
Type: In Type you can select the type of path to be displayed in the view frame. The
selectable types are Owner path and Non-owner path.
When using the TagmaStore AMS/WMS series, Thunder 9500V Series, or Thunder 9200
By default, both the Owner path and Non-owner path check boxes are selected.
The Type specification has priority over the Status specification. For example, if you
select only the Owner path option in Type, the Configuration view will display only
the owner paths whose statuses are selected in the Status check boxes.
When you clear the Owner path check box or Non-owner path check box, the
Configuration view narrows down the displayed paths accordingly.
Note that the Type settings remain in effect even when you click the Path List tab
and switch to the Path List view.
Owner path check box: When you select Owner path, the Configuration view
displays owner paths.
Non-owner path check box: When you select Non-owner path, the Configuration
view displays non-owner paths.
When using the TagmaStore USP, Lightning 9900V Series, or Lightning 9900 Series
In Type you can select the type of path to be displayed in the Configuration view.
Since all paths are owner paths, only the Owner path check box is displayed as
active.