HiCommand Dynamic Link Manager (HDLM) for Windows Systems User's Guide (HIT5201-96001, January 2008)

232 Chapter 7 Command Reference
Setting
Automatic
Failback
Intermittent
Error
Monitoring
Available Operation Result of Operation
Set intermittent error monitoring to
on.
When a path is being monitored (in the period of
conditional intermittent error monitoring), the value of
the error count and the elapsed monitoring time are
reset to
0, and then intermittent error monitoring
restarts.
When a path is not being monitored (outside the
period of conditional intermittent error monitoring),
nothing changes.
Change the intermittent error
monitoring settings.
When a path is being monitored (in the period of
conditional intermittent error monitoring), the value of
the error count and the elapsed monitoring time are
reset to 0, and then intermittent error monitoring
restarts according to the conditions for intermittent
error after change.
1
When a path is not being monitored (outside the
period of conditional intermittent error monitoring), the
intermittent error monitoring settings will take effect
when the path is recovered from the error status by
performing automatic failback.
Set intermittent error monitoring to
off.
Intermittent error monitoring is disabled.
The error count, elapsed monitoring time, and
information about paths not subject to automatic
failback are cleared.
Set automatic failback to on. The operations of automatic failback and intermittent error
monitoring do not change.
Change the automatic failback
setting.
Automatic failback operates using new settings.
off
Set automatic failback to off. Automatic failback is disabled.
on off Set intermittent error monitoring to
on.
Intermittent error monitoring is enabled.
1
Set automatic failback to on. Automatic failback and intermittent error monitoring are
enabled.
1
on
2
Set automatic failback to
off. The operations of automatic failback and intermittent error
monitoring do not change.
Set automatic failback to on. Automatic failback is enabled.
off
off
Set automatic failback to off. The operations of automatic failback and intermittent error
monitoring do not change.
1
When this condition is not satisfied, the KAPL01080-W message is output and an error occurs. The status of the intermittent
error monitoring does not change.