HiCommand Dynamic Link Manager (HDLM) for Windows Systems User's Guide (HIT5201-96001, January 2008)

HiCommand
®
Dynamic Link Manager (HDLM) for Windows
®
Systems User’s Guide 39
Figure 2.14 Action Conditions for Intermittent Error Change during Error Monitoring
2.8.4 When User Operations Change Intermittent Error Information
The following might be reset when the user changes the values set for an intermittent error
or the path status: the number of errors that are counted during error monitoring, the time
that has passed since error monitoring started, and the information about whether an
intermittent error occurs (the path has been removed from those paths subject to automatic
failback).
Table 2.6 lists whether the above items are reset.
If you want to check whether intermittent error monitoring is being performed for the path,
check the IEP item displayed when the dlnkmgr command's view -path operation is
executed with the -iem parameter or the Intermittent Error Path item in the Path List view
of the HDLM GUI. If a numerical value of 0 or greater is displayed in the Intermittent Error
Path item, then intermittent error monitoring is being performed.
Table 2.6 When User Operations change Intermittent Error Information
User Operation
Number of Errors and
Time Passed since Error
Monitoring Started
Information about Paths
not Subject to
Automatic Failback
Setting off Reset Reset
1
Changing the conditions for an
intermittent error during intermittent
error monitoring
Setting on during intermittent error
monitoring by executing the
set
operation (the conditions for the
intermittent error monitoring are not
changed)
Changing the setting for
intermittent error
monitoring
Clicking the Apply or OK button in
the window for the Options window
of the HDLM GUI.
#3
during
intermittent error monitoring
Reset
2
Inherit