3. Creating an HDLM Environment
149
1. In the Hitachi Network Objectplaza Trace Library setup menu, type 1 and then
press the Enter key.
A screen to set the size of the integrated trace file will appear. The current value
is displayed in Current Size (KB).
2. Enter the desired size in New Size (KB).
The specifiable range is between 8 KB and 8192 KB, with a default of 256. Set
this to a value larger than that set in step 2 of 3.8.5 Changing the Buffer Size Per
Monitoring Interval Duration. We recommend setting a value of 4096 when
collecting an integrated trace.
If you do not want to change the integrated trace file size, leave New Size (KB)
blank, type
!, and then press the Enter key to return to the Hitachi Network
Objectplaza Trace Library setup menu.
3. Press the Enter key.
The new setting is applied and the Hitachi Network Objectplaza Trace Library
setup menu appears again.
3.8.4 Changing the Number of Integrated Trace Files
The following procedure shows how to change the number of integrated trace files.
To change the number of integrated trace files:
1. In the Hitachi Network Objectplaza Trace Library setup menu, type
2 and then
press the Enter key.
A screen to set the number of integrated trace files will appear. The current value
is displayed in Current Number (KB).