Hitachi Dynamic Link Manager Software Users Guide for AIX (6.6) (T5208-96010, April 2011)

8. Messages
357
the DLMgetras utility, see 7.2 DLMgetras Utility for Collecting HDLM
Error Information.
KAPL01021-E
Cannot execute the HDLM command due to insufficient memory.
Details
Memory required for HDLM command processing could not be allocated.
Action
Terminate unneeded applications to increase the amount of free memory, and then
retry.
KAPL01023-W
The last Online path for the device cannot be placed Offline(C).
Details
The path specified in the
offline operation cannot be placed in the
Offline(C) status because it is the last path for the applicable logical unit.
Action
Use the
view operation of the HDLM command (dlnkmgr) to check the status
of the paths. For details on the
view operation, see 6.7 view (Displays
Information).
KAPL01024-W
The specified parameters cannot be specified at the same time.
Operation name = aa...aa, parameters = bb...bb
Details
aa...aa:
clear, offline, online, set, or view
bb...bb:Parameters that cannot be specified at the same time
Action
Execute
help operation of the HDLM command (dlnkmgr) to check which
parameters can be specified at the same time, and then retry. For details on the
help
operation, see 6.3 help (Displays the Operation Format).
KAPL01036-E
The Offline path cannot be placed online. PathID = aa...aa
Details
aa...aa: Path ID (decimal (base-10) number)
Action
Remove the error in the path, and then retry.