Hitachi Dynamic Link Manager Software Users Guide for AIX (6.6) (T5208-96010, April 2011)

8. Messages
379
KAPL04012-E
Could not create a communication pipe. RC = aa...aa
Details
HDLM manager could not start normally because it was unable to create a pipe
file, which is used in communication with HDLM commands.
aa...aa: OS error code (decimal (base-10) number)
Action
Execute the
DLMgetras utility for collecting HDLM error information, and then
contact your HDLM vendor or the maintenance company if there is a maintenance
contract for HDLM. For details on the
DLMgetras utility, see 7.2 DLMgetras
Utility for Collecting HDLM Error Information.
KAPL04013-E
Input is impossible via the communication pipe. RC = aa...aa
Details
Data could not be read from the pipe file while communicating with an HDLM
command.
aa...aa: OS error code (decimal (base-10) number)
Action
Execute the
DLMgetras utility for collecting HDLM error information, and then
contact your HDLM vendor or the maintenance company if there is a maintenance
contract for HDLM. For details on the
DLMgetras utility, see 7.2 DLMgetras
Utility for Collecting HDLM Error Information.
KAPL04014-E
Output is impossible via the communication pipe. RC = aa...aa
Details
Data could not be written to the pipe file while communicating with an HDLM
command.
aa...aa: OS error code (decimal (base-10) number)
Action
Execute the
DLMgetras utility for collecting HDLM error information, and then
contact your HDLM vendor or the maintenance company if there is a maintenance
contract for HDLM. For details on the
DLMgetras utility, see 7.2 DLMgetras
Utility for Collecting HDLM Error Information.
KAPL04019-E
Could not collect the error information. RC = aa...aa