KAPL10049-I
Error information collection command = aa...aa, Return value =
bb...bb, Execution time = cc...cc
Details
A command was executed to collect information targeted for collection.
aa...aa: Executed command
bb...bb: Return value of the executed command
cc...cc: year (4 digits)/month/date hour:minute:second
Action
None.
KAPL10050-I
The utility for collecting HDLM error information started. Start
time = aa...aa (GMT aa...aa)
Details
The utility for collecting HDLM error information started.
aa...aa: year (4 digits)/month/date hour:minute:second
Action
None.
KAPL10521-W
A parameter is invalid. (parameter = aa...aa)
Details
aa...aa: invalid parameter (character string)
Action
Execute help of the
dlmrmdev utility to check the parameters that can be
specified, and then retry.
For details on the
dlmrmdev utility, see 7.11 dlmrmdev Utility for Deleting
HDLM Drivers.
KAPL10523-E
An attempt to unmount the file system has failed. (file system
= aa...aa)