HiCommand Dynamic Link Manager (HDLM) for Windows Systems User's Guide (HIT5201-96001, January 2008)

104 Chapter 3 Creating an HDLM Environment
8. Specify a license key file or enter a license key in accordance with the instructions
shown in the messages that appear on the window. If a license key file was stored in
step 5, specify that license key file. If a license key file is not used, specify the license
key directly.
9. Enter user information in accordance with the instructions shown in the messages that
appear on the window.
10. Specify the installation folder in accordance with the instructions shown in the messages
that appear on the window.
11. The utility for registering HDLM persistent reservation keys (dlmprsvkey) is
automatically executed to create a PRSV key. The PRSV key is required for the HDLM
functions to operate normally. Also, the value of the PRSV key must be unique among
hosts. Creation of the PRSV key may be unsuccessful if, for example, an NIC does not
exist. Do one of the following in accordance with the result of the execution of the
dlmprsvkey utility:
If the key creation is successful, the created PRSV key appears in the dialog box. If
you do not need to change the value, click the Next button. If you must change the
value because another host already has the same PRSV key, change the value, and
then click the Next button. If you want to undo the change, click the Back button
and then start over from step 10.
If the creation is unsuccessful, a dialog box appears that prompts you for the PRSV
key. Enter the PRSV key, and then click the OK button.
For the values you can specify for the PRSV key, follow the instructions shown in the
installation program window.
12. The program checks the PRSV key. If the KAPL09128-W message appears, follow the
procedure below:
You are prompted to re-enter the PRSV key. Enter an appropriate PRSV key. The
program then checks the PRSV key again.
If no message appears, go to the next step.
13. The message Select Storage System to be managed. is displayed: click the Next button.
In an Oracle RAC environment, the EMC DMX series and EMC CX series cannot be set as
an HDLM management-target device. Thus, do not select EMC Symmetrix DMX Series,
CLARiiON CX Series. Similarly, the HP EVA series cannot be set as an HDLM
management-target device. Accordingly, do not select HP StorageWorks EVA Series
either.
14. Follow the instructions shown in the messages that appear on the window.
If a dialog box that begins with the following sentence appears during installation,
and the Storport Miniport driver is used as the HBA driver, stop the HDLM
installation. Then, install QFE838894 or a later version of the Microsoft Storport
driver, or install Windows Server 2003 SP1 or later.
Notes on using a Storport Miniport driver:
Read these notes before using a Storport Miniport driver as an HBA driver.
The file version of the Storport.sys of this system (Microsoft Storport driver) is
n.n.nnnn.n.