HiCommand Dynamic Link Manager (HDLM) for Windows Systems User's Guide (HIT5201-96001, January 2008)

HiCommand
®
Dynamic Link Manager (HDLM) for Windows
®
Systems User’s Guide 107
31. Make sure that the program is working normally, by examining the results of the
dlnkmgr command's view operation.
An example of executing the dlnkmgr command's view operation is as follows:
>dlnkmgr view -sys
HDLM Version : xx-xx
Service Pack Version :
Load Balance : on(rr)
Support Cluster : off
Elog Level : 3
Elog File Size (KB) : 9900
Number Of Elog Files : 2
Trace Level : 0
Trace File Size(KB) : 1000
Number Of Trace Files : 4
Path Health Checking : on(30)
Auto Failback : off
Remove LU : off
Intermittent Error Monitor : off
HDLM Manager Ver WakeupTime
Alive xx-xx yyyy/mm/dd hh:mm:ss
HDLM Alert Driver Ver WakeupTime ElogMem Size
Alive xx-xx yyyy/mm/dd hh:mm:ss 128
HDLM Driver Ver WakeupTime
Alive xx-xx yyyy/mm/dd hh:mm:ss
License Type Expiration
Permanent -
KAPL01001-I The HDLM command completed normally. Operation name = view, completion
time = yyyy/mm/dd hh:mm:ss
Even if you are using Oracle RAC, off appears for Support Cluster. Regardless, the
cluster support function runs normally.
3.6.4 Upgrade Installation or Re-installation of HDLM
You can perform an upgrade installation for HDLM 5.5 or later only. To migrate HDLM 5.4 or
earlier to version 5.5 or later, see section
3.6.5.
The procedure for an upgrade installation or re-installation is the same as for a new
installation of HDLM, except for the following steps:
Executing the dlmchkpath utility for checking HDLM paths.
The dlmchkpath utility is executed automatically when the installation program
(setup.exe) starts. The dlmchkpath utility checks whether the system is in a single-
path configuration. If a warning dialog box appears, reconfigure the system into a single-
path configuration, and then perform the upgrade installation or re-installation again.
Note, however, that when an unattended installation is used and the system is
determined to be in a multi-path configuration, an HDLM upgrade installation or re-
installation will end without displaying any warning dialog boxes.
Entering the license key.
The window displays the type and expiration date of the license key, which were
entered when HDLM was installed for the first time. If the license key has expired, the
procedure is the same as for a new installation.
Entering user information and specifying the installation folder.