HiCommand Dynamic Link Manager (HDLM) for Windows Systems User's Guide (HIT5201-96001, January 2008)

HiCommand
®
Dynamic Link Manager (HDLM) for Windows
®
Systems User’s Guide 255
Displayed Item
No Summary
Displayed
1
Summary
Displayed
2
Description
IEP Not displayed Information about the intermittent error. This item is displayed only when you specify -
iem
with the -path parameter. One of the following values is displayed for each path:
- indicates that intermittent error monitoring is disabled or the monitoring time for
an intermittent error is out of range (the path status is Online(E) or Offline(E)).
A value of at least 0 indicates the number of errors that occurred during intermittent
error monitoring (the path status is Online(E), Offline(E), or Online).
* indicates that an intermittent error occurred (automatic failback does not check
the path) (the path status is Online, Online(E), or Offline(C)).
1
No summary displayed indicates that the user specifies the -path parameter or -path -item parameter.
2
Summary displayed indicates that the user specifies the -path -c parameter.
3
The path information is displayed only when a value is specified for the -path -item parameter.
4
In a cluster configuration, an offline operation requested during reserve processing is put into the waiting-to-execute state,
and does not execute until the reserve processing finishes.
5
The drive letter assigned to a dynamic disk volume is not displayed.
Table 7.12 describes the elements of a path name.
Table 7.12 Elements of a Path Name
Element Windows Representation
Host port number (hexadecimal) (example: 0004, 0005) SCSI port number
Bus number (example: 0001) SCSI bus number
Target ID (example: 0000000000000000,
000000000000007A)
Target Id
Host LU number0001) Logical Unit ID or LUN
The path name corresponds to the following information:
Information shown in the Computer Management window.
The information in the following registry:
HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\Scsi
Note: When an FC connection is used, the target ID of a SCSI is determined based on the HBA
configuration. For details on the target ID, see the relevant documentation, such as the HBA
manual.