HiCommand Dynamic Link Manager (HDLM) for Windows Systems User's Guide (HIT5201-96001, January 2008)

HiCommand
®
Dynamic Link Manager (HDLM) for Windows
®
Systems User’s Guide 63
In Windows Server 2003 (x64), do not create the data stored in the GUID Partition Table
(GPT).
When installing HDLM, The name of the HDLM installation folder and the names of all its
parent folders must fulfill all of the following conditions:
The name must not be a reserved name specified in the operating system.
Reserved names specified in the operating system include, for example, CON, AUX,
COM1 to COM9, LPT1 to LPT9, PRN, and NUL.
The name must contain the following characters only:
A - Z, a - z, 0 - 9, -, _, ., @, or a single byte space
The end of the name cannot be a single byte space.
The name cannot contain two or more single byte spaces consecutively.
If you attempt to install the HDLM in a folder that does not fulfill these conditions,
problems such as those described in
Table 3.9 might occur. In such a case, reinstall the
HDLM according to the procedures given below.
Table 3.9 Error Log Collection Level Setting Values
Problem Action
An internal error occurred and the installation was interrupted. Specify a folder that fulfills the above conditions and
reinstall the HDLM.
After the installation finished, error information could not be
collected when you executed the
DLMgetras utility for
collecting HDLM error information.
Uninstall the HDLM and then install it again specifying a
folder that fulfills the above conditions.
3.4.5 Notes on Related Software
If HDLM is installed on a host in which the MPIO driver has already been installed, the
MPIO driver that is bundled with the HDLM CD-ROM overwrites the existing MPIO driver.
The MPIO driver consists of the mpio.sys, mpspfltr.sys, and mpdev.sys files.
Do not install any multi-path management software other than HDLM. If multi-path
management software other than HDLM has been installed on the host, uninstall the
software, and then restart the host before re-installing HDLM.
If you perform an upgrade installation or re-installation of HDLM, a message might
appear, asking you to confirm whether you want to overwrite the MPIO driver. If this
message appears, stop the installation, make sure that no other multi-path management
software is installed, and then retry the installation.
If you use HDLM with Oracle RAC 10g and the following conditions are satisfied, you must
change the settings for Oracle RAC 10g after building the environment.
Release of 10.1.0.3.0 or later of Oracle RAC 10g is being used.
A host and a voting disk are connected by multiple paths (in a multi-path
configuration) in an FC-SAN environment.