Medical Archive Solutions User Guide

HPMA User Guide
176
HP Medical Archive
CsQT Count of CMS Synchronization messages
that are queued to be sent to other CMS
services.
More than 50,000 is considered a minor
alarm to investigate further. More than
1,000,000 is considered a critical
condition.
Ensure that other CMS services
are online and running normally.
Check the load on the system—if
there have been a significant
number of transactions this may
be normal and will resolve itself
over time.
If the alarm persists, view a chart
of the queue size. If the number
continues increasing without ever
decreasing, contact HP technical
support.
DBSF Remaining Database Space; the number
of bytes remaining in the allocated
database for CMS metadata.
Adjusting the alarm threshold allows you
to proactively manage when additional
storage needs to be allocated.
If the available space is reaching a
low threshold, you should contact
HP technical support to arrange
for the database allocation to be
enlarged.
DCiN Number of unprocessed new content
objects.
More than 1000 is considered cause for
investigation.
If the number persists for some
time after new content has been
stored, contact HP technical
support.
Attr.
Code
Description Recommended Action