Medical Archive Solutions User Guide

HPMA User Guide
184
HP Medical Archive
NCMS Number of CMSs the device is connected
to.
The system needs multiple CMSs to
maintain fault tolerance and quality of
service.
If there is no connected CMS under
LDR
X Network, there are no CMSs avail-
able and end user functionality may be
impacted.
If there is no connected CMS under
CMS
X Network, there is at least one CMS
running (itself) and system operation is
not impacted.
Restore connectivity to a CMS as
soon as possible. This may require
updating authentication
certificates.
If the condition persists, contact
HP technical support.
NDBC NMS Database component Connectivity
status:
0 = Connecting...
1=Connected
2 = Connection Lost, Reconnecting...
3 = Connection Timeout, Retrying...
4 = Authentication Failed, Retrying...
If the service indicates “Authenti-
cation Failed, Retrying...”, restart
the service. If the problem persists,
contact HP technical support.
NDUP Network Duplex setting:
0=Full
1=Half
2 = Unavailable
3=Unknown
4 = Unsupported
Check the network adapter config-
uration. The setting must match
preferences of your network
routers and switches.
An incorrect setting can have a
severe impact on grid
performance.
NLNK Network Link Detect:
0=Down
1=Up
2 = Unavailable
3=Unknown
4 = Unsupported
Check the network cable connec-
tions on the port and at the switch.
Check the network router, switch,
and adapter configurations.
Restart the server.
If the problem persists, contact HP
technical support.
Attr.
Code