HP 3PAR OS 3.1.2 MU5 Release Notes

Table Of Contents
DescriptionItemIssue ID
The electrical signal which indicates a severe
thermal event is not handled properly, which
HP 3PAR OS generates false "Cluster thermal
shutdown" events.
81540
sometimes results in false "Cluster thermal
shutdown" event reports. This is resolved.
SMI-S provider fails if an array has an all-numeric
name (the name as shown in showsys). This is
resolved.
SMI-S Provider initialization fails if an array has
an all-numeric name.
81685
To ensure that cage requests are handled
successfully, timeout values and other functionalities
are improved.
Cage requests handling improved.81901
Resolved an issue where calling
HideLUsFromStorageHardwareIDCollection results
in occasional "Invalid ProtocolControllers" failure.
Resolved an issue where calling
HideLUsFromStorageHardwareIDCollection
results in occasional "Invalid ProtocolControllers"
failure.
81925
Added support for SNMPv3 trap. A user can
specify the trap version (v2 or v3) for a particular
Added support for SNMPv3 trap.82090
SNMP manager. SNMPv3 traps are encrypted
with CFB128-AES-128 and authenticated with
HMAC-SHA-96 hash.
An EEPROM read operation interrupted by a
power failure alert can leave the EEPROM device
Resolved an issue that causes portion of the
node EEPROM to be overwritten. The most
82094
in write mode. An issue in the Nemoe codecommon location overwritten is the Node ID,
prevents the read operation from being completed.but the Midplane Type, NodeType or other
A recovery behavior in the Intel PCH chipfields may be affected. In rare cases, the
Ethernet MAC Address may be erased. recognizes the stalled read operation and attempts
a bus reset after a timeout causing a single byte
write to be received by the EEPROM, overwriting
data at the address where the read is interrupted.
This only occurs when a node is powered off and
timing of the power fail signal interrupts an
EEPROM read. This is resolved. It correctly handles
the power fail interrupt and allows the EEPROM
read operation to complete so that the PCH timeout
and bus recovery are not triggered.
After calling CreateElementReplica, without
specifying the input TargetElement parameter to
Both output Job and TargetElement parameters
are NULL if calling CreateElementReplica without
82106
create a clone, the output Job and TargetElementspecifying the input TargetElement parameter
to create a clone. parameters are both NULL. The corresponding
TPD_ConcreteJob instance is also missing. This is
resolved.
ModifySynchronization/
ModifyReplicaSynchronization Resync operation
ModifySynchronization/
ModifyReplicaSynchronization Resync operation
82107
on an asynchronous clone results in target volumeon an asynchronous clone results in target
volume getting detached. getting detached after the resynchronization. This
is resolved.
To ensure successful cage firmware downloads,
retry operation is added.
Retries are added to cage firmware download.82122
An issue prevents the parsing of the manufacturing
record on various FRU parts of the DCN1, DCS1,
An issue prevents the parsing of the
manufacturing record on various FRU parts of
the DCN1, DCS1, DCS2 cages.
82123
DCS2 cages. This is resolved. All of the
manufacturing data can be read and displayed.
RAID level information is added to ElementName
string of StorageSetting that has ChangeableType
of "Fixed - Not Changeable" (0).
RAID level information is included in
ElementName of fixed StorageSetting.
82303
When enqueueing control and management
requests to the fibre channel HBA, the driver
System becomes unresponsive to commands
under certain circumstances.
82464
38 HP 3PAR OS 3.1.2 MU2 Release Notes