HP 3PAR OS 3.1.2 MU5 Release Notes

Table Of Contents
DescriptionItemIssue ID
The following set of cage alerts repeat continuously,
if any of the associate issues is present:
A subset of cage alerts continuously repeat.88805
Cage temperature fault
Audible alarm fault
Display fault
Cage not supported fault
Bad link speed
This is resolved.
Improved the handling of PCM Fans, as follows:Improved handling of 7000 Series PCM Fans.88812
1. The processing of the fan tolerance warning is
improved
2. The fan speed and ramp up are stabilized.
For HP 3PAR OS 3.1.1 GA, the shownode env
command do not display all the node environmental
Resolved an issue that causes the shownode env
command to show partial node environmental
information on F-class systems.
88873
information on F-class systems. Due to this, some
hardware errors are not detected in early stage. The
issue exists with subsequent HP 3PAR OS 3.1.1 MU
and 3.1.2 releases. This issue is resolved and the
shownodeenv command displays the full
environmental table.
When running the ddump command to dump the
cage data, it previously use to truncate its output
The ddump command does not truncate its output.88929
intermittently. More time is allowed for completion
of the command, so that the output is not truncated.
This resolves an issue of inquiry commands to the
3PAR vendor unique LUN page (0xC0h) timing out
Inquiry requests to LUN Vendor Unique Page timeout
during upgrades from HP 3PAR OS 3.1.1 to HP
3PAR OS 3.1.2 or later versions.
89348
from Hosts during upgrades from HP 3PAR OS 3.1.1
to HP 3PAR OS 3.1.2 or later versions.
Resolved an issue where a node running HP 3PAR
OS 3.1.2 MU2 becomes unresponsive and results
Resolved an issue where a node running HP 3PAR
OS 3.1.2 MU2 becomes unresponsive and results
89407
in data unavailability when a rcopy transaction login data unavailability when a rcopy transaction log
is converted to the new format on nodes running HPis converted to the new format on nodes running
3PAR OS 3.1.2 MU2 during online upgrade from
previous HP 3PAR OS releases.
HP 3PAR OS 3.1.2 MU2 during online upgrade
from previous HP 3PAR OS releases.
HP 3PAR has specific recommendations documented
in the installation guides on zoning configuration. If
Zoning configuration issues.89893
these recommendations are not followed, HP 3PAR
target ports might see a large number of initiator
(host) ports in a single zone. In such poorly zoned
environments, under certain circumstances, the Fibre
Channel driver might trigger a port reset if enqueued
requests are not serviced in a timely manner. An
issue in the driver causes a node to become
unresponsive during or shortly after such a reset. This
issue is resolved in the releases HP 3PAR OS version
3.1.1 MU4, HP 3PAR OS version 3.1.2 MU3, and
HP 3PAR OS version 3.1.3 and it is carried forward.
Wrong frame originated by some Fabric switches
causes the Storeserv port to go down. The is resolved
and such frames are filtered out.
Wrong frame originated by some Fabric switches
causes the Storeserv port to go down.
90034
Correctly initialize the status field in free-volume-space
request messages to prevent the message being sent
to the server node twice.
Resolved an uninitialized variable issue in log page
message.
90079
Previously, the PCMs in DCS1 (LFF) cages were
reported as 0 for the lower-right PCM and 1 for the
DCS1 PCM numbers reported by the CLI now match
the documentation.
90166
Modifications to the HP 3PAR OS 53