3PAR InForm Operating System and Administration Tools 2.2.4 MU6 Release Notes

4
Release 2.2.4 MU6 Release Notes InForm OS Version 2.2.4
3.0 What’s New in the InForm OS
1 New drive support is included in 3PAR InForm OS Release 2.2.4 MU6.
Support for higher-capacity 600GB 15K Fibre Channel Drives is now available.
2 Support for new host platform configurations.
Microsoft Windows 2008 R2 is now supported.
VMware ESX 4.0 with iSCSI is now supported.
Reference the 3PAR Configuration Matrix for 2.2.4 and 2.3.1 for details.
4.0 Modifications to the InForm OS
The following items have been addressed in this release.
Bug ID Item Description
38093 SCSI reservations
should not be blocked
by the system manager
configuration lock.
Some long-running system operations, (such as dynamic
optimizations for large volumes), could occasionally result
in SCSI-2 reservations not being handled in a timely manner,
and VMware ESX hosts seeing high IO latencies.
This has been fixed by handling SCSI-2 reservations more
efficiently even while the system is busy with long-running
operations.
39666 Incorrect termination
of some SCSI control
commands during a
Fibre Channel port
reset causes the
controller node to
restart.
When a Fibre Channel adapter port was reset, the controller
node could sometimes go offline due to a validity check
failing due to certain host SCSI commands, (such as Test Unit
Ready), being incorrectly marked as completed prior to the
status being returned to the host.