HP 3PAR InForm OS 3.1.1 MU1 Release Notes

DescriptionItemBug ID
Workaround: Pass virtual volume sets that are not empty to the
createvvcopy command.
The CLI shell is a TCL-based shell, as such it parses integers with leading
0 (zero) as octal numbers, just like many other languages and shells (bash,
Integer arguments to CLI
commands with leading 0
45413
perl, etc). Consequently, integer arguments passed to the CLI commands
are also treated as octal numbers if they have a leading 0.
(zeros) are treated as octal
numbers.
Workaround: If you do not wish for integers to be treated as octal integers,
do not use leading zeros.
The showcage -sfp command shows the sfp state as OK, Degraded,
Failed or Unknown. For an unqualified SFP, the state should be Degraded
but is shown as OK.
Drive cage displays do not
correctly report degraded
SFPs.
46372
Workaround: If showcage sfp shows an SFP as OK, try using
showcage sfp d <cage_name>. If the Qualified field shows No,
then it is an unqualified SFP and its state should be deemed as Degraded.
The matching of a user’s extended group (basic_edit-map, create-map,
3PAR_AO-map, 3PAR_RM-map) supersedes static groups (super-map,
service-map, edit-map, browse-map).
Extended groups supersede
static groups
51356
Workaround: If there are multiple group matches, the first match determines
the user’s role.
createsched does not support [ and ] globbing characters.createsched does not
support [ and ] globbing
characters.
57362
Workaround: These characters cannot be used when specifying a pattern
with the createsched command.
The combination of sasl-mechanism set to GSSAPI and binding set to
simple does not function properly.
sasl-mechanism set to
GSSAPI and binding set to
simple not functional.
59715
Workaround: Set sasl-mechanism to GSSAPI and binding to sasl
instead.
If CTRL+C is pressed while HP 3PAR Peer Motion Manager Software is
processing a batch file, processing stops and the Migration Manager
Wizard exists.
HP 3PAR Peer Motion
Manager Software exits
during batch file processing.
59796
The servicecage command's specifier 0|1 is required for many
subcommands including staretfc and endfc in order for the command
to function properly.
servicecage syntax is
incorrect.
60105
Pressing R in order to return to the previous menu does not refresh the
screen.
In HP 3PAR Peer Motion
Manager Software, pressing
R does not refresh the screen.
60980
Workaround: To refresh the screen, press Enter.
When an invalid option is entered, the showport command displays the
message Expecting <NSP or pattern> got: -a instead of Invalid option: -a
and the command usage.
showport command
displays incorrect error
message.
63624
If a BBU is marked permanently failed and is replaced, the permanent
failure does not get cleared (for any fault and the BBU's status indicates
Failed Battery Backup Unit
(BBU) does not clear its status
64033
Failed as shown by the showbattery command and the associatedand issue a pending alert
when replaced.
pending alert does not resolve. To work around this issue, run the
nemoetool -z [-n <node#>] command on a root shell ( not the CLI
shell).
30 HP 3PAR InForm OS CLI Release Notes