HP 3PAR InForm OS 3.1.1 MU1 Release Notes

5 InForm OS 3.1.1 MU1 CLI Release Notes
Removed and Deprecated Commands and Options
The following commands have been removed or deprecated in the InForm OS 3.1.1 MU1 release.
Removed Commands and Options
The CLI command removeeventlog has been removed.removeeventlogLogs
Modifications to the InForm OS CLI
DescriptionItemBug ID
When using the createvvcopy command with virtual volume sets, if both
sets are empty, the output of the command erroneously references the
creategroupvvcopy command.
Misleading command
output when passing
empty virtual volume sets
to the createvvcopy
command
44937
CLI command showcage -sfp showed the state of an unqualified SFP in
the cage as OK. It should show as Degraded.
Unsupported SFP is now
shown in CLI
commandshowcage
-sfp as Degraded
46372
If a BBU is marked permanently failed and is replaced, the permanent failure
does not get cleared (for any fault and the BBU's status indicates Failed as
Failed Battery Backup Unit
(BBU) does not clear its
64033
shown by the showbattery command and the associated pending alert
does not resolve.
status and issue a pending
alert when replaced.
In InForm OS 3.1.1 or earlier releases, the following error message may
appear when the CLI client is launched by multiple-threads with a secure
connection:
CLI client secure
connection can now be
launched by multiple
threads
65525
Could not open a connection to CLI server process on "s018": -sockssl option
not supported, libtls not loaded System name may be invalid, or the process
may not have started yet or may have failed.
The problem has been fixed in InForm OS 3.1.1 MU1 and the CLI client secure
connection can now be launched by multiple-threads concurrently.
A warning message is prompted to the user when they select RAID-5 and NL
drive combination. The warning message suggests that RAID-6 would provide
RAID-5 and Nearline
drive warning message
65997
better availability and reliability for NL drives. The user can override the
warning message by using the -f option.
Warning message: HP strongly recommends RAID-6 for high capacity NL
drives. Do you wish to continue?
The following CLI commands are affected: createaldvv, growaldvv, tunealdvv,
createcpg, setcpg.
Removed and Deprecated Commands and Options 37