HP 3PAR Online Import for EMC Storage Data Migration Guide

SMI-S Provider Server Logs and Output
When an issue occurs, get all the SMI–S Provider server logs and output to assist with
troubleshooting. Use the following action and commands to get the logs and output.
Go to this file location to get the SMI–S Provider logs:
Windows: C:\Program Files\EMC\ECIM\ECOM\log\cimomlog
Get SMI–S Provider output by issuing these commands:
dv command to see SMI–S Provider version information and lists of storage systems being
managed by SMI-S Provider.
Example 29 dv command
(localhost:5988) ? dv
eq command to see storage system information in the format that is being passed to the
EMC Plugin for all storage systems being managed by the SMI–S Provider.
NOTE: Select statement parameters are case-sensitive and should be entered as displayed
below.
Example 30 eq command
(localhost:5988) ? eq
Query Language[DMTF:CQL]:
Query []: select Tag,ElementName,Manufacturer,Model from Clar_ArrayChassis
Increase the SMI–S Provider Server Logging Level
Perform the following to set the SMI–S log to the most verbose level:
1. Login to the ECOM administration interface.
2. Select Log Options.
3. Set the Log file to CIMOMLOG.
4. Set the Log Severity to NAVI_TRACE.
5. Set Trace Settings to turn on all 3 traces.
6. Save the Log Setting.
Troubleshooting Communication Between OIU Server and SMI–S Provider
1. In the OIU server, issue the showsource command.
2. Execute the desired URL from the OIU server
Secure: https://<SMI–S Server IP address>:<port>/ecomconfig
Unsecure: http://<SMI–S Server IP address>:<port>/ecomconfig
3. Replace these variables:
<SMI–S Server IP address> with the “Management_Server” IP address displayed in
OIU:showsource
<port> with the Port that was used when the addsource command was executed
The unsecure port default is 5988
The secure port default is 5989
48 Troubleshooting