3PAR InForm® OS 2.2.4 Concepts Guide (320-200085 Rev B, March 2009)

12.4
Drive Cage Models
3PAR InForm OS Concepts Guide InForm OS Version 2.2.4
12.1.2 DC2 and DC4 Ports and Cabling
The DC2 and DC4 drive cages contain two FCAL modules for connecting the drive cage to the
controller nodes. The left-hand FCAL module has two ports: A0 and B0, and the right-hand
FCAL module has two ports: A1, and B1.
Fibre Channel cables connect the Fibre Channel ports in the drive cage to the ports on the
controller nodes. Each cable is labeled to indicate the ports it uses (Figure 12-3):
Figure 12-3. Cable Labels for FCAL Module to Node Connections
NOTE: Daisy chaining is not supported for the DC2 or DC4 drive cages.
0234_L_R1
(Cxx.x) Nx:Sx:Px <
> (Cxx.x) Dx:Px
Cabinet and Bay
(Node Cabinet)
Node Fibre Channel
Adapter Port
Cabinet and Bay
(Drive Chassis
Cabinet)
Drive Chassis Drive
Cage Port
NOTE: For detailed information about ports, Fibre Channel adapters, cabling, and
cable configurations, refer to the 3PAR InServ S-Class/T-Class Storage Server
Physical Planning Manual or the 3PAR InServ E-Class/F-Class Storage Server and
Third-Party Rack Physical Planning Manual.