3PAR InForm OS 2.3.1 MU2 Release Note (325-200142 Rev B, October 2010)

2.17
Known Issues with the InForm OS
InForm OS Version 2.3.1 MU2 3PAR InForm OS Release Notes
3PAR Confidential
2.7.17 Some Messages Not Clear During upgradecage
(Bug 45229)
Messages displayed during an upgrade of a drive cage are not clear if the drive cage is actually
being upgraded.
Workaround - Run the showcage and showcage -d command to see if a firmware upgrade
is still required. Verify there are no other instances of upgradecage running, then run
upgradecage again.
2.7.18 showtask for updatevv Displays Incorrect Completion Time
(Bug 46328)
showtask for updatevv displays the incorrect completion time.
Workaround - In these cases updatevv did complete for all virtual volumes in the set,
however the completion time is incorrect. The actual completion time can found by
gathering the creation time of the new snapshots.
NOTE: This was observed when multiple upgradecage commands were run. Do
not run multiple upgradecage commands.