3PAR InForm OS 2.3.1 MU2 Release Note (325-200142 Rev B, October 2010)

3.6
Known Issues with the InForm CLI
3PAR InForm OS Release Notes InForm OS Version 2.3.1 MU2
3PAR Confidential
46372 Drive cage displays do not
correctly report degraded
SFPs.
The showcage -sfp command shows the sfp state as
OK, Degraded, Failed or Unknown. For an
unqualified SFP, the state should be Degraded but is
shown as OK.
Workaround: If showcage –sfp shows an SFP as OK,
try using showcage –sfp –d <cage_name>. If the
Qualified field shows No, then it is an unqualified SFP
and its state should be deemed as Degraded.
47270 Discrepancy between
showsys -space and
showvv -r data for base
volumes.
There are two issues associated with this bug.
1 Base volume space is double counted.
This problem has already been fixed in 2.3.1 GA and
also back ported to 2.2.4 MU6 (bug 31892 and 45225).
2 The raw used space is calculated wrong for RAID 5 and
RAID 6 Logical Disks.
In this case, the
showcpg –r and showsys –space
command output will display wrong information.
Bug 48234 is opened to track this problem.