HP 3PAR Management Console 4.3.1 Release Notes (QL226-96859, April 2013)

DescriptionItemBug ID
option has been removed in order to improve performance. The user
can view the task by manually opening the Task Manager.
The group DN field in the LDAP configuration wizard did not support
the space character. Now, the user can enter a space character in
the group DN field.
The LDAP group DN field should allow a
space character
83421
The DC state of the power supply is not present in the non-EOS
systems, which causes the HP 3PAR Management Console system
The HP 3PAR Management Console
system summary detail panel shows the
83450
summary detail panel to display the power supply status for all cagespower supply status for all cages as
unknown for non-EOS systems as unknown. To prevent this, an EOS system check has been added
before displaying the DC state.
When "Create additional targets..." is checked, the Finish button is
not enabled until there are 4 links of mixed mode 1-1 Remote Copy
configuration.
Remote Copy configuration wizard should
not allow the user to continue with only 2
links in 1-1 mixed mode
83679
When a host in an iSCSI configuration uses the same IQN with
different IP addresses, the Management Console Host manager
The HP 3PAR Management Console Host
manager incorrectly shows a higher count
of iSCSI initiators than the actual number.
84760
continually shows an incremental count of iSCSI initiators instead of
the actual number, and eventually runs out of memory. The correct
number of initiators is now displayed.
1.4 Known Issues with the HP 3PAR Management Console
1.4.1 The Management Console Might Run out of Memory when Left Running (Bug
44409)
The Management Console might eventually run out of memory and require a restart if it is connected
to multiple HP 3PAR StoreServ Storage systems and left running for days. This issue occurs when the
Java Virtual Machine (JVM) does not release memory back to the operating system even after garbage
collection has occurred and even when the Management Console is not using all the memory allocated
by the JVM.
Workaround:
None.
1.4.2 The Management Console Fails during a Rolling Upgade (Bug 46452)
A Management Console fatal error occurs when a rolling upgrade is performed on the HP 3PAR
StoreServ Storage system.
Workaround:
When performing a rolling upgrade on an HP 3PAR StoreServ Storage system, shut down all instances
of the Management Console that are connected to that HP 3PAR StoreServ Storage system.
1.4.3 Converting Existing Remote Copy 1-to-1 Configurations to Synchronous Long
Distance (SLD) Not Supported (Bug 48421)
The Management Console currently does not support conversion of an existing Remote Copy 1-to-1
configuration to a Synchronous Long Distance configuration. Providing this conversion will be addressed
in a future release.
Workaround:
Use HP 3PAR OS CLI commands to convert a 1-to-1 configuration to a Synchronous Long Distance
configuration.
1.4 Known Issues with the HP 3PAR Management Console 5