Solution: On a restarted migration, if an OIU:showmigration command shows FAILED status
unexpectedly, wait 1–2 minutes and issue the OIU:showmigration command again. You should
see the proper IMPORTING status. If the status continues to remain at FAILED, the migration has
failed.
HP 3PAR Online Import Utility for EMC Storage Error Messages
OIUERRSRC0020 = "Unsupported EMC storage system version ";
OIURSLSRC0020 = "Check support matrix and upgrade EMC.";
Problem: Source EMC Storage system version check Failed.
Solution: Source EMC Storage system must be running at supported version.
OIUERRSRC0111 = "Unable to present the volume to the host in EMC array";
OIURSLSRC0111 = "Contact HP Support if the problem persists.";
Problem: Unable to add 3PAR peer port host to source storage system group.
Solution: Check the OIU log file for specific description of the problem from SMI-S Provider.
OIUERRSRC0112 = "Unable to unpresent the volume from the host in EMC array"
OIURSLSRC0112 = "Contact HP Support if the problem persists."
Problem: Unable to remove 3PAR peer port host from source storage system group.
Solution: Check the OIU log file for specific description of the problem from SMI-S Provider.
OIUERRSRC0021 = "There is a active migration on this source. So this source can not
be removed.";
OIURSLSRC0021 = "Migration have to be complete/abort for source to be removed.";
Problem: Tried to execute OIU:removemigration while the specified migration is still in progress.
Solution: Wait for migration to complete before removing.
OIUERRSRC0022 = "Cannot find specified source Array.";
OIURSLSRC0022 = "An Array has to be added first in order to be removed."
Problem: Tried to execute OIU:removesource with specific UID and that UID does not exist in OIU database.
Solution: Execute OIU:showsource to determine storage systems that are currently known.
OIUERRSRC0023 = "You have selected a migration with an unsupported storage group
configuration."
OIURSLSRC0023 = "Verify that your storage group configuration matched one of the
supported configurations."
Problem: LUN associated with createmigration that was executed is not in a supported storage group configuration.
Solution: Review supported storage group configurations in section “Supported and Unsupported Migrations by HP
3PAR Online Import Utility for EMC Storage (page 17) and make appropriate changes before creating the migration.
OIUERRAPP0013 = "Unsupported EMC Provider version for SMI-S"
OIURSLAPP0013 = "Check support matrix and upgrade EMC Provider."
Problem: The SMI-S Provider that was entered is running an unsupported version.
Solution: Storage systems for migration must be managed by SMI-S Provider with supported version.
OIUERRAPP0009 = "Job might have executed successfully but couldn't receive any handle
to track it.";
OIURSLAPP0009 = "Contact HP Support"
Problem: Problem occurred during SMI-S related job.
Solution: Check the OIU log file for specific description of the problem. HP support may be required.
OIUERRAPP0010 = "SMI-S EMC Provider WBEM Operations error.";
OIURSLAPP0010 = "Please check SMI-S ECOM connectivity and access, see Log file for
details, and/or Contact HP Support."
HP 3PAR Online Import Utility for EMC Storage Error Messages 57