HP 3PAR Online Import for EMC Storage Data Migration Guide

Problem: It could be communication problem, or access problem.
Solution: Logs will have exact cause as an exception trace. There could be configuration (remote IP access, local access)
of the ECOM required to be rectified.
OIUERRAPP0011 = "EMC Provider WBEM Connection, Malformed URL.";
OIURSLAPP0011 = "Application internal error, see Log file for details. Contact HP
Support."
Problem: This would indicate a defect in accessing the provider due to incorrect protocol (HTTP, HTTPS allowed), or
no protocol at all.
Solution: Try different combinations of secure settings and port in the OIU command. Verify enabled ports on the
SMI-S provider.
OIUERRAPP0012 = "EMC Provider WBEM Connection, Client initialization error.";
OIURSLAPP0012 = "Application internal error, see Log file for details. Contact HP
Support."
Problem: This might be caused by blank user name or password when connecting to SMI-S provider.
Solution: Ensure that username and password are specified.
OIUERRAPP0015 = "SMI-S EMC Provider Connection error.";
OIURSLAPP0015 = "Please check SMI-S ECOM connectivity (IP Address, Port number), see
Log file for details, and/or Contact HP Support."
Problem: Wrong IP or Wrong Port specified for SMI-S Provider.
Solution: Use correct SMI-S Provider and IP address.
OIUERRAPP0016 = "SMI-S EMC Provider Authorization error.";
OIURSLAPP0016 = "Please check SMI-S ECOM Access Configuration and/or User Credentials,
see Log file for details, and/or Contact HP Support."
Problem: Wrong SMI-S Provider credentials or OIU not on trusted client IP address list.
Solution: Use correct SMI-S Provider credentials. If Trusted IP Address list is enabled, make sure OIU server is on the
trusted IP address list on the ECOM server.
58 Troubleshooting