setbattery
DESCRIPTION
The setbattery command sets battery information such as the battery’s expiration date, its
recharging time, and its serial number. This information gives the system administrator a record
or log of the battery age and battery charge status.
SYNTAX
setbattery [options <arg>] <node_ID> <powersupply_ID> <battery_ID>
setbattery [options <arg>] <node_ID>
AUTHORITY
Super, Service
Any role granted the battery_set right.
NOTE: You need access to all domains in order to run this command.
OPTIONS
s <serial_number>
Specifies the serial number of the battery using a limit of eight alphanumeric characters.
x <exp_date>
Specifies the expiration date of the battery (mm/dd/yyyy). The expiration date cannot extend
beyond 2037.
l
Specifies that the battery test log is reset and all previous test log entries are cleared.
r
Specifies that the battery recharge time is reset and that 10 hours of charging time are required
for the battery to be fully charged.
SPECIFIERS
<node_ID>
Specifies the node number where the battery is installed.
<powersupply_ID>
Specifies the power supply number on the node using either 0 (left side from the rear of the node)
or 1 (right side from the rear of the node).
<battery_ID>
Specifies the battery number on the power supply where 0 is the first battery.
NOTE: The <powersupply_ID> and <battery_ID> specifiers can be obtained from the output of
the showbattery command.
RESTRICTIONS
Access to all domains is required to run this command.