HP 3PAR OS 3.1.3 Command Line Interface Reference
State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC4
Unique_ID 1062010000001C00
Power Supply Info State Fan State AC Model
ps0 OK OK OK POI
ps1 OK OK OK POI
ps2 OK OK OK POI
ps3 OK OK OK POI
-----Magazine Info----- ---State---
Mag SysLED HplLED Disks LoopA LoopB
0 Green Off 4 Ready Ready
1 Green Off 4 Ready Ready
2 Green Off 4 Ready Ready
...
9 Green Off 4 Ready Ready
-------------Drive Info------------- ----LoopA----- ----LoopB-----
Drive NodeWWN LED Temp(C) ALPA LoopState ALPA LoopState
0:0 2000001862c4e410 Green 31 0xe1 OK 0xe1 OK
0:1 2000001862c4e3f6 Green 31 0xe0 OK 0xe0 OK
0:2 2000001862c4e3bc Green 28 0xdc OK 0xdc OK
...
9:1 2000001862b9affb Green 30 0xa6 OK 0xa6 OK
9:2 2000001862b9b035 Green 27 0xa5 OK 0xa5 OK
9:3 2000001862b9b7b5 Green 25 0xa3 OK 0xa3 OK
When the power supply is switched off, it will be reported as Off through the showcage -d
command as well as a degraded alert being posted. The following is a sample of the output:
cli% showcage -d cage3 | egrep -i 'Power|\<ps'
Power Supply Info State Fan State AC Model
ps0 OK OK OK MAG
ps1 Off OK OK MAG
ps2 Failed OK Failed MAG
ps3 OK OK OK MAG
cli% showalert | grep Cage\ 3
Message : Cage 3, Power Supply 1 Degraded (Power Supply Off)
Message : Cage 3, Power Supply 2 Failed (Power Supply Failed, Power Supply AC
Failed)
NOTES
The power supply model, as shown in the Model column of the showcage –d output, is set by
service personnel using the setcage command, as described in “setcage” (page 268).
showcage 353