HP 3PAR OS 3.1.3 Command Line Interface Reference

State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC4
Unique_ID 1062010000001C00
Power Supply Info State Fan State AC Model
ps0 OK OK OK POI
ps1 OK OK OK POI
ps2 OK OK OK POI
ps3 OK OK OK POI
-----Magazine Info----- ---State---
Mag SysLED HplLED Disks LoopA LoopB
0 Green Off 4 Ready Ready
1 Green Off 4 Ready Ready
2 Green Off 4 Ready Ready
...
9 Green Off 4 Ready Ready
-------------Drive Info------------- ----LoopA----- ----LoopB-----
Drive NodeWWN LED Temp(C) ALPA LoopState ALPA LoopState
0:0 2000001862c4e410 Green 31 0xe1 OK 0xe1 OK
0:1 2000001862c4e3f6 Green 31 0xe0 OK 0xe0 OK
0:2 2000001862c4e3bc Green 28 0xdc OK 0xdc OK
...
9:1 2000001862b9affb Green 30 0xa6 OK 0xa6 OK
9:2 2000001862b9b035 Green 27 0xa5 OK 0xa5 OK
9:3 2000001862b9b7b5 Green 25 0xa3 OK 0xa3 OK
When the power supply is switched off, it will be reported as Off through the showcage -d
command as well as a degraded alert being posted. The following is a sample of the output:
cli% showcage -d cage3 | egrep -i 'Power|\<ps'
Power Supply Info State Fan State AC Model
ps0 OK OK OK MAG
ps1 Off OK OK MAG
ps2 Failed OK Failed MAG
ps3 OK OK OK MAG
cli% showalert | grep Cage\ 3
Message : Cage 3, Power Supply 1 Degraded (Power Supply Off)
Message : Cage 3, Power Supply 2 Failed (Power Supply Failed, Power Supply AC
Failed)
NOTES
The power supply model, as shown in the Model column of the showcage d output, is set by
service personnel using the setcage command, as described in setcage” (page 268).
showcage 353