HP 3PAR OS 3.1.3 Command Line Interface Reference
◦ NotPresent. The battery is missing.
◦ MaxLifeLow. The maximum battery life is low.
• ChrgLvl. The battery charge level in percentage.
The following example displays the detailed state of the nodes:
cli% shownode -state
Node -State- -Detailed_State-
0 OK OK
1 OK OK
2 OK OK
3 OK OK
In the example above:
• Node. The node ID.
• State. The state of the node. Values are as follows:
OK. The node and its components are operating normally.◦
◦ Degraded. The node is degraded when the power supply is missing, failed, or degraded
(fan failed, battery max life low, failed, expired, or not present).
◦ Failed. The node is either not initialized, offline, kernel revision mismatched, disk
partition bad, rebooting, or shut down.
• Detailed_State. The detailed state of the node. Values are as follows:
tod_bat_fail. The time of day battery failed.◦
◦ invalid_bat_config. The battery has an invalid configuration.
◦ link_error. The node has a link error.
◦ uncorrectable_mem_error. The node has an uncorrectable memory error.
◦ multi_uncorrectable_mem_error. The node has multiple uncorrectable memory
error.
◦ correctable_mem_error. The node has a correctable memory error.
◦ internal_system_error. The node has an internal system error.
◦ hardware_watchdog_error. The node has a hardware watchdog error.
◦ pci_error. There is a PCI error in the node.
◦ driver_software_error. The node has a driver software error.
◦ cpu_overheating. The node CPU overheating.
◦ cpu_vrm_overheating. The node CPU VRM overheating.
◦ control_cache_dimm_overheating. The node Control Cache DIMM is overheating.
◦ node_offline_due_to_failure. The node is offline due to failure.
◦ node_shutdown_manually. The node was shutdown manually.
◦ unknown. The node state is unknown.
406 Show Commands