HP 3PAR OS 3.1.3 Command Line Interface Reference
The following example displays the detailed state of the power supplies:
cli% shownode -ps
Node PS -State- -Detailed_State-
0 0 OK OK
1 1 OK OK
2 2 OK OK
3 3 OK OK
In the example above:
• Node. The node ID.
• PS. The power supply ID.
• State. The power supply state. Values are as follows:
OK. The power supply is operating normally.◦
◦ Failed. The power supply is operating abnormally.
◦ NotPresent. The power supply is missing.
◦ Degraded. The fan failure or battery state is not OK.
• Detailed_State. The power supply detailed state. Values are as follows:
invalid_bat_count. The power supply has an invalid battery count.◦
◦ dc_failed. The power supply DC failed.
◦ ac_failed. The power supply AC failed.
◦ fan_failed. The power supply fan failed.
◦ charger_overload. The power supply charger overloaded.
◦ battery_not_present. The power supply battery is not present.
◦ invalid_firmware. The power supply firmware is invalid.
◦ oscillating_presence. The power supply presence is oscillating.
◦ oscillating_dc. The power supply DC is oscillating.
◦ oscillating_ac. The power supply AC is oscillating.
◦ oscillating_fan. The power supply fan is oscillating.
◦ oscillating_charger. The power supply charger is oscillating.
◦ oscillating_bat. The power supply battery is oscillating.
◦ NotPresent. The power supply is not present.
◦ unknown. The power supply state is unknown.
NOTES
None
shownode 407