HP 3PAR OS 3.1.3 Release Notes

DescriptionItemIssue ID
To verify that the date specified in setdate is correct, the proposed date
and time is displayed to the user and a confirmation to continue is
requested. To skip the confirmation prompt, the -f option can be used.
A user confirmation prompt is
provided for setting the date
at the CLI.
66440
New CLI command promotegroupsv is added.Batch based promotes for
VVs.
75452
New CLI client support on AIX 6.1 and AIX 7.1 is added. Disk Space
requirements are as follows:
CLI client now supports AIX
6.1 and AIX 7.1
84204
Installer: 105 MB
Temp space: 290 MB
Installed space: 90 MB
New Retryable Exit Status
(code 10)
84211 1. To enable retryable exit status, the CLI user must do one of the following:
Set TPDCLIENHERROR
Use -enherror CLI option
2. Exit status other than 1
Some customer scripts (internal and external) might be using a
hard-coded value of 1 (if error equals to one) to check for an error. If
another non-zero value is returned for an error, the customer script
might fail in that case. If a customer script is currently using a non-zero
value to check error, then the customer is not affected by this change.
Earlier VV Sets could be only displayed with their current membership,
making historical SR data potentially inaccurate if accessed by set. This
Earlier VV Sets could be only
displayed with their current
86167
limitation is resolved. Furthermore, VVSET_NAME might be used as a valid
column for use with the groupby option to the srvvspace command.
membership, making
historical SR data potentially
inaccurate if accessed by set.
Earlier VV or host sets could be only displayed with their current
membership, making historical SR data potentially inaccurate if accessed
Expanded set capability.86168
by set. This limitation is resolved. Furthermore, VVSET_NAME and
HOSTSET_NAME might be used as valid columns for use with the groupby
option.
The -oneline option is added to sraomoves command. This option
prints the output for each aocfg in one line with totals.
Enhancements to the
sraomoves command.
87135
The srstatport and srhistport CLI commands are enhanced with
the ability to select specific port types and specific set of ports to consider.
Enhancements to the
srstatport and
srhistport commands.
87138
A new port_type option is added to select specific port types and port
selection pattern specifiers are added.
When checkupgrade cannot read connections, it displays following
error:
Resolved an issue where
checkupgrade cannot read
connections.
87160
can't read "connections(123456789ABCDEF1)": no such
element in array.
The checkupgrade script is updated to resolve this issue.
A new -aocfg <aocfg_name> option is added to the showcpg
command. This option allows users to only include CPGs that are part of
the aocfg <aocfg_name>.
A new option, -aocfg, is
added to showcpg
command.
87894
New options, -cumul and -pct, are added to srrgiodensity
command. These options display data in cumulative format and as a
percentage respectively.
New options, -cumul and
-pct, are added to
srrgiodensity command.
89855
If the -withvv option is specified in the srrgiodensitycommand, the
VV information is included in the output.
If the -withvv option is
specified in the
91044
srrgiodensity command,
the VV information is included
in the output.
26 HP 3PAR CLI Release Notes