HP 3PAR OS 3.1.3 Upgrade Instructions

total Data t 0 0 0 0 0.0 0.0 0.0 0.0 -
Press the enter key to stop...
7. Type exit and press Enter to exit the interactive CLI and return to SPMAINT main menu to
begin an HP 3PAR OS offline update.
8. From the SPMAINT main menu, type =4.7.3, and select the menu number corresponding to
the system to update, then press Enter.
9. Choose the option 3 for offline upgrade type and press Enter.
10. Select the menu number corresponding to 3.1.3.230-MU1 and press Enter.
4.7 StoreServ Upgrade
Available OS levels
1 ==> 3.1.3.230-MU1
2 ==> 3.1.3.202-GA
3 ==> 3.1.2.484
4 ==> 3.1.2.422
5 ==> REVERT-3.1.2.484
Select 0 to abort
Please select an Software level to apply
11. The following confirmation message is displayed:
We are about to commence the offline upgrade on StoreServ s945 to 3.1.3.230-MU1
Are you certain you wish to proceed?
(y or n)
y
Type y and press Enter.
12. Type the five—digit number that displays to confirm the update and press Enter.
For example:
Please re-enter the following number - 35789 (x to quit) :35789
The duration of the update process varies depending on the system configuration.
13. When the update process is completed, press Enter to return to the SPMAINT main menu.
14. Verify the health of the storage system. For more information, see “Verifying the Health of the
Storage System (page 13).
15. From the SPMAINT menu, enter: =7 , then press Enter to start a CLI session from the SPMAINT
main menu. Issue the shownode command to verify that all controller nodes have joined the
cluster again.
16. Issue the showversion -a -b command to verify that the system is running HP 3PAR OS
3.1.3.230.
<StoreServ_Name> cli% showversion -a -b
Release version 3.1.3.230
Patches:
...
17. Type exit and press Enter to exit the CLI session and return to the SPMAINT main menu.
21