HP 3PAR Recovery Manager 4.4.2 for Microsoft Exchange 2007, 2010, and 2013 User Guide

Table 10 HP 3PAR Recovery Manager Software for Microsoft Exchange Event Messages (continued)
Description/ActionError MessageEvent ID
The authentication data has been corrupted on your system.
Rerun the configuration setup for this specific HP 3PAR StoreServ
Storage System.
3PARVSS3818: ERROR: Unable
to encrypt/decrypt
authentication data. Additional
information: <Exception
Message>.
3818
An invalid log level has been specified.
Make sure the specified log level range is from 1 to 5.
3PARVSS3819: ERROR: Invalid
log level specified. The valid
range is 1 to 5.
3819
The log level setup could not be accessed.
Make sure you have the proper permission and privilege to access
the registry setup.
3PARVSS3820: ERROR: Unable
to access log level setup.
3820
An attempt to spawn an HP 3PAR OS Command Line Interface (CLI)
process has failed.
Make sure you have the CLI installed on your system and that it is
registered in the system environment variable’s PATH.
3PARVSS3821: ERROR: Fail to
spawn an InForm CLI process.
3821
No existing HP 3PAR StoreServ Storage System configuration entry
could be located.
3PARVSS3822: There is no
existing Storage System
configuration entry.
3822
You must have at least one HP 3PAR StoreServ Storage System
configuration entry.
Use the configuration tool to add the appropriate entry to the list.
The specified volume snapshot attribute is not supported by HP 3PAR
VSS Provider Software.
Please refer to the latest version of the HP 3PAR VSS Provider
Software for Microsoft Windows User’s Guide for a list of supported
features.
3PARVSS5050: ERROR:
Unsupported feature <Feature
Name>.
5050
Microsoft VSS only allows a maximum of 64 volumes to participate in
a snapshot process.
3PARVSS5051: ERROR: The
shadow copy set has exceeded
5051
the maximum number (64) of
allowable volumes.
This type of memory allocation failure can result from a system-wide
contention for resources.
Check the event log for more detailed information.
RM5052: ERROR: Could not
allocate memory.
5052
This problem can be caused by incorrect authentication setup, the
unavailability of a CLI tool, or a licensing issue.
3PARVSS5053: ERROR: Could
not communicate with the 3PAR
InForm CLI.
5053
Verify the HP 3PAR OS Command Line Interface (CLI) installation.
Check to make sure the bin subfolder is in PATH.
Check the Application Log of the Event Viewer for more information.
The command submitted to the CLI has generated an error.
Check the Application Log of the Event Viewer for more information.
3PARVSS5054: ERROR: CLI:
<command>.
5054
Unable to identify requested information received from the HP 3PAR
StoreServ Storage System.
3PARVSS5055: ERROR:
<Token>: Invalid token.
5055
Check that your HP 3PAR StoreServ Storage System version is
supported by HP 3PAR VSS Provider and that there are no network
problems that could result in a partial data transmission.
To determine the version for a particular HP 3PAR StoreServ Storage
System, run the showversion command.
For the HP 3PAR VSS Provider version, run vssadmin list
providers and check the HP 3PAR VSS Provider entry that specifies
the version and other details.
157