HP 3PAR System Reporter 2.9 MU1 Software Release Notes Abstract This document provides Release Notes for HP 3PAR System Reporter 2.9 MU1 Software. Provided in this document are a list of known issues that may be visible to the customer. Read this entire document before installing System Reporter.
© Copyright 2011 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
HP 3PAR System Reporter 2.9 MU1 Requirements Supported HP 3PAR System Reporter 2.9 MU1 Host Platforms Component Requirement Operating System Microsoft Windows Server 2008 R2 (32- or 64-bit), or Microsoft Windows 2003 (32- or 64-bit), or Red Hat Enterprise Linux 5.6 (32-bit only if using Oracle, 32- or 64-bit otherwise). Processor Intel Pentium 4 processor, 3 GHz or higher.
MySQL is the recommended database. The MySQL database may be on a remote database server host, not necessarily on the machine on which System Reporter is installed. • Oracle (not included) must be obtained and installed separate from HP 3PAR System Reporter 2.9 Software. Oracle version 11g is supported. Performance of sample insertion with Oracle is a little lower than that of MySQL but Oracle is also a good choice for large databases.
Defects Fixed in HP 3PAR System Reporter 2.9 MU1 Bug Description Resolution Adaptive License check fails if the CLI connection for an HP 3PAR Storage Optimization System is terminated by the network (e.g., a timeout occurs). intermittently fails during license check. The CLI connection is now checked before starting new region moves and, if necessary, the CLI connection is restarted. Higher A problem occurs when generating VLUN perf reports for nodes with numbered slots more than 7 PCI slots.
Item Description The files resulting from the processing of the extraction utility can be large. The extracted files are stored in ASCII files with line feed, tab and spaces so the size of the extraction file can be much larger than the data stored in the database. Workaround: None. The Excel client is designed to have This limitation has been set to prevent Excel from hanging. a maximum of 30 sheets open at a Workaround: time. None. The Excel client can hang in the middle of some navigation.