AB378A Fibre Channel Mass Storage Adapter Installation Guide, December 2005

Fibre Channel Adapter Installation
Verifying Connectivity
Chapter 1
13
fcp 8 0/0/10/1/0.1 fcd_fcp CLAIMED INTERFACE FCP Domain
ext_bus 44 0/0/10/1/0.1.17.0.0 fcd_vbus CLAIMED INTERFACE FCP Array Interface
target 135 0/0/10/1/0.1.17.0.0.0 tgt CLAIMED DEVICE
disk 867 0/0/10/1/0.1.17.0.0.0.0 sdisk CLAIMED DEVICE HP OPEN-9
/dev/dsk/c44t0d0 /dev/rdsk/c44t0d0
disk 871 0/0/10/1/0.1.17.0.0.0.1 sdisk CLAIMED DEVICE HP OPEN-9
/dev/dsk/c44t0d1 /dev/rdsk/c44t0d1
Verifying Connectivity
Once your HP Fibre Channel Mass Storage software and hardware is installed and running, type the
following commands to verify mass storage hardware and software installation.
1. Check the state of all Fibre Channel hardware and interfaces. Enter the ioscan command and verify that
the Hardware State and the HW-Interface State are CLAIMED.
If the Fibre Channel device file has not been created, enter the following commands:
insf -e
ioscan -f
2. Verify that all devices you attached to the Fibre Channel adapter are listed in the ioscan output. For
example, if you have a direct attach Fibre Channel device attached to the system, the ioscan output might
look like the following:
8/12.8.0.255.0.1.0 sdisk CLAIMED DEVICE DGC C3400WDR5
The example above is the hardware path of LUN0 of a directly attached Fibre Channel Mass Storage
device with Loop ID of 1.
3. HP Fibre Channel Mass Storage installation is verified if the ioscan output lists all mass storage devices
attached to the adapter. If all attached devices are not listed or appear as UNCLAIMED, see the
Troubleshooting and Maintenance chapter of the HP Fibre Channel Adapters Support Guide.
Verify that the link speed at both ends of any cable are auto-negotiated to the highest common speed.
Run the fcmsutil /dev/fcd# command to check the link speed.
If the AB378A is connected to a switch port that is set in ASN mode or set at 4Gb, Link Speed should
display 4Gb.
If the switch port is set at 2Gb, Link Speed should display 2Gb.
If the switch port is set at 1Gb, Link Speed should display 1Gb.
Interpreting Hardware Paths
The following illustration is the Fibre Channel hardware path format: