Management and Configuration Guide K/KA/KB.15.15

Syntax
ip timep manual <ip-addr>
This activates TimeP in manual mode with a specified TimeP server. (By default,
SNTP traffic goes through the data ports.)
Example 3 Configuring TimeP for manual operation
To select TimeP and configure it for manual operation using a TimeP server address
of 10.28.227.141 and the default poll interval (720 minutes, assuming the TimeP
poll interval is already set to the default):
(HP_Switch_name#) timesync time
Selects TimeP and activates TimeP in manual mode:
(HP_Switch_name#) timesync timep
(HP_Switch_name#) ip timep manual 10.28.227.141
(HP_Switch_name#) show timep
Timep Configuration
Time Sync Mode: Timep
TimeP Mode : Manual Server Address : 10.28.227.141
Poll Interval (min) : 720
Viewing, enabling, and modifying the TimeP protocol (Menu)
1. From the Main Menu, select:
2. Switch Configuration
1. System Information
Figure 5 System Information screen (default values)
2. Press [E] (for Edit.)
The cursor moves to the System Name field.
3. Use â to move the cursor to the Time Sync Method field.
4. If TIMEP is not already selected, use the Space bar to select TIMEP, then press â once to display
and move to the TIMEP Mode field.
28 Time Protocols